Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 60: 1461-1465, 1986;
8750-7587/86 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by O'Brodovich, H.
Right arrow Articles by Marrin, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by O'Brodovich, H.
Right arrow Articles by Marrin, M.

Journal of Applied Physiology, Vol 60, Issue 5 1461-1465, Copyright © 1986 by American Physiological Society


ARTICLES

Effect of inspiratory resistance and PEEP on 99mTc-DTPA clearance

H. O'Brodovich, G. Coates and M. Marrin

Experiments were performed to determine the effect of markedly negative pleural pressure (Ppl) or positive end-expiratory pressure (PEEP) on the pulmonary clearance (k) of technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). A submicronic aerosol containing 99mTc-DTPA was insufflated into the lungs of anesthetized intubated sheep. In six experiments k was 0.44 +/- 0.46% (SD)/min during the initial 30 min and was unchanged during the subsequent 30-min interval [k = 0.21 +/- 12%/min] when there was markedly increased inspiratory resistance. A 3-mm-diam orifice in the inspiratory tubing created the resistance. It resulted on average in a 13-cmH2O decrease in inspiratory Ppl. In eight additional experiments sheep were exposed to 2, 10, and 15 cmH2O PEEP (20 min at each level). During 2 cmH2O PEEP k = 0.47 +/- 0.15%/min, and clearance increased slightly at 10 cmH2O PEEP [0.76 +/- 0.28%/min, P less than 0.01]. When PEEP was increased to 15 cmH2O a marked increase in clearance occurred [k = 1.95 +/- 1.08%/min, P less than 0.001]. The experiments demonstrate that markedly negative inspiratory pressures do not accelerate the clearance of 99mTc-DTPA from normal lungs. The effect of PEEP on k is nonlinear, with large effects being seen only with very large increases in PEEP.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
J. Widdicombe
Airway and alveolar permeability and surface liquid thickness: theory
J Appl Physiol, January 1, 1997; 82(1): 3 - 12.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
D. DREYFUSS and G. SAUMON
Ventilator-induced Lung Injury . Lessons from Experimental Studies
Am. J. Respir. Crit. Care Med., January 1, 1997; 157(1): 294 - 323.
[Full Text]