Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 60: 876-884, 1986;
8750-7587/86 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Menon, A. S.
Right arrow Articles by Chang, H. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Menon, A. S.
Right arrow Articles by Chang, H. K.

Journal of Applied Physiology, Vol 60, Issue 3 876-884, Copyright © 1986 by American Physiological Society


ARTICLES

Velocity profiles in central airways with endotracheal intubation: a model study

A. S. Menon, M. E. Weber and H. K. Chang

Steady inspiratory velocity profiles were measured at two flow rates in a 3:1 scale model of the human central airways in the presence of five modes of endotracheal intubation. The presence of an orifice or a short endotracheal tube had no significant effect on the velocity profiles distal to the carina. Long endotracheal tubes change the profiles in both main bronchi. A significant peak occurred in the frontal plane near the walls, and the maximum velocity in the airway was almost identical to the endotracheal tube center-line velocity. The flow impinging on the medial wall of the main bronchus was redirected up around the anterior and posterior walls yielding bipeak velocity profiles in the sagittal plane. A tube placed eccentrically in the trachea over the right main bronchus did not alter the velocity profiles in the left main bronchus, suggesting a redirection of flow over the carina into the left lung. An endobronchial tube at the mouth of the right main bronchus did change the shape of the velocity profiles in the left main bronchus. In the left upper lobar bronchus the presence of trachea intubation had no effect on the velocity profiles. However, in the right upper lobar bronchus, the long endotracheal tube flattened the velocity profiles from the strongly skewed ones seen in the absence of the endotracheal inserts. These results not only are relevant to distribution of ventilation and aerosol particle deposition, but also have strong implications in intrapulmonary gas mixing, especially when high-frequency low tidal-volume ventilation is involved.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
L. de Rochefort, L. Vial, R. Fodil, X. Maitre, B. Louis, D. Isabey, G. Caillibotte, M. Thiriet, J. Bittoun, E. Durand, et al.
In vitro validation of computational fluid dynamic simulation in human proximal airways with hyperpolarized 3He magnetic resonance phase-contrast velocimetry
J Appl Physiol, May 1, 2007; 102(5): 2012 - 2023.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online