Journal of Applied Physiology Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 60: 846-853, 1986;
8750-7587/86 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Olgiati, R.
Right arrow Articles by Cerretelli, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Olgiati, R.
Right arrow Articles by Cerretelli, P.

Journal of Applied Physiology, Vol 60, Issue 3 846-853, Copyright © 1986 by American Physiological Society


ARTICLES

Hemodynamic effects of resistive breathing

R. Olgiati, G. Atchou and P. Cerretelli

To examine the acute hemodynamic effects induced by large swings in intrathoracic pressure such as may be generated by obstructive lung disease, airway obstruction was simulated by means of two different fixed external alinear resistances and the results were compared with those for unobstructed breathing (C). Eight normal subjects breathed through external resistances during inspiration (I), expiration (E), or both (IE) at rest (Re) and exercise (Ex). The resistances were chosen to induce similar mouth pressure (Pm) swings at Re and Ex. Pleural pressures (Ppl) were found to correlate closely with Pm. During IE resistive breathing mean swings in Pm were -31 and +19 cmH2O at Re and -38 and +22 cmH2O at Ex, with a corresponding decrease in minute ventilation (-30 and -18%) and an increase in end-tidal PCO2 (+5.6 and +4.2 Torr); these were associated with an increase in heart rate (delta HR = 4 and 6 beats/min) and systolic systemic arterial pressure (delta Psas = 10 and 14 Torr at Re and Ex, respectively). O2 consumption and cardiac output did not change. The myocardial O2 consumption, estimated from the product HR X (Psas--Ppl), increased by 17 and 20% at Re and Ex, respectively. Changes in mechanics, gas exchange, and hemodynamics were less pronounced during I or E resistive loading. It is concluded that breathing through a tight external resistance during IE at Re and Ex increases the metabolic load on the myocardium.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
L. Chen and S. M. Scharf
Systemic and myocardial hemodynamics during periodic obstructive apneas in sedated pigs
J Appl Physiol, April 1, 1998; 84(4): 1289 - 1298.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
I. Iandelli, A. Aliverti, B. Kayser, R. Dellaca, S. J. Cala, R. Duranti, S. Kelly, G. Scano, P. Sliwinski, S. Yan, et al.
Determinants of exercise performance in normal men with externally imposed expiratory flow limitation
J Appl Physiol, May 1, 2002; 92(5): 1943 - 1952.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online