Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 60: 630-637, 1986;
8750-7587/86 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Christensen, W. D.
Right arrow Articles by Swift, D. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Christensen, W. D.
Right arrow Articles by Swift, D. L.

Journal of Applied Physiology, Vol 60, Issue 2 630-637, Copyright © 1986 by American Physiological Society


ARTICLES

Aerosol deposition and flow limitation in a compliant tube

W. D. Christensen and D. L. Swift

Studies in intact dogs have suggested that aerosol deposition is enhanced in the proximity of a flow-limiting segment (FLS) formed during cough. The mechanism for that observation was investigated using a monodisperse (geometric SD less than or equal to 1.15) fluorescent aerosol produced in a condensation generator. The aerosol was passed through a compliant tube (Penrose) that had been mounted vertically in a two-chamber box. The surrounding pressure (Ps) in the upstream chamber was controlled independent of the surrounding pressure in the downstream chamber, thus allowing development of an FLS near the exit of the upstream chamber. At fixed inlet pressure (P1) and Ps, flow limitation was achieved over a range of 0.1-0.5 l X s-1 by lowering downstream pressure alone (P2). The influence of the FLS cross-sectional geometry on the site of peak deposition was examined because area of an FLS is a function of transmural pressure (Ptm = Px - Ps). For those constriction geometries that did not involve opposing wall contact, the deposition distribution was characterized by a single peak immediately downstream of the constriction. In the most compressed geometries the peak in deposition was diminished and shifted further downstream. Total aerosol deposition was found to be characterized by a dimensionless particle inertia parameter formed as the ratio of particle stopping distance and the minor radius of the elliptical tube cross section. The deposition of small particles with an inertial parameter less than 0.01 was found to be independent of geometry and constriction velocity.(ABSTRACT TRUNCATED AT 250 WORDS)





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online