Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 60: 260-265, 1986;
8750-7587/86 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miles, D. S.
Right arrow Articles by Sexson, W. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miles, D. S.
Right arrow Articles by Sexson, W. R.

Journal of Applied Physiology, Vol 60, Issue 1 260-265, Copyright © 1986 by American Physiological Society


ARTICLES

Evaluation of impedance cardiography in the canine pup

D. S. Miles, R. W. Gotshall and W. R. Sexson

This study evaluated the use of the noninvasive technique of impedance cardiography to assess central hemodynamics in an animal model similar in size to the neonate. Seven canine pups 5-6 wk of age, with an average weight of 2.2 kg, were studied. To alter cardiac output (Q), the pups were given 12 and 8% O2 to breathe, which produced an arterial PO2 of 30 and 21 Torr, respectively. Q was obtained simultaneously by impedance and thermal dilution under both normoxic and hypoxic conditions. The average Q measured by impedance and thermal dilution were within 10% agreement and moderately correlated (r = 0.76). Impedance Q and stroke volume (SV) averaged 201 ml X min-1 X kg-1 and 2.8 ml, respectively. Thermal dilution Q and SV averaged 212 ml X min-1 X kg-1 and 2.9 ml, respectively. Individual responses to the hyoxemia were variable, but the impedance technique appeared to measure these individual responses as well as the thermal-dilution technique. These findings demonstrate that impedance cardiography may be suitable to assess either the absolute or relative changes in central hemodynamics. The use of this technique in critical care neonatal and pediatric medicine seems justified.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
G. Manier, M. Duclos, L. Arsac, J. Moinard, and F. Laurent
Distribution of lung density after strenuous, prolonged exercise
J Appl Physiol, July 1, 1999; 87(1): 83 - 89.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online