Journal of Applied Physiology, Vol 59, Issue 4 1104-1109, Copyright © 1985 by American Physiological Society
ARTICLES |
W. E. Truog and T. A. Standaert
We studied the effects of conventional mechanical ventilation (CMV) (15 ml/kg tidal volume delivered at 18-25 breaths/min) and high-frequency oscillatory ventilation (HFOV) (less than or equal to 2 ml/kg delivered at 10 Hz) on pulmonary hemodynamics and gas exchange during ambient air breathing and hypoxic gas breathing in 10 4-day-old lambs. After instrumentation and randomization to either HFOV or CMV the animals breathed first ambient air and then hypoxic gas (inspired O2 fraction = 0.13) for 20 min. The mode of ventilation was then changed, and the normoxic and hypoxic gas challenges were repeated. The multiple inert gas elimination technique was utilized to assess gas exchange. There was a significant increase with HFOV in mean pulmonary arterial pressure (Ppa) (20.1 +/- 4.2 vs. 22 +/- 3.8 Torr, CMV vs. HFOV, P less than 0.05) during ambient air breathing. During hypoxic gas breathing Ppa was also greater with HFOV than with CMV (29.5 +/- 5.7 vs. 34 +/- 3.1 Torr, CMV vs. HFOV, P less than 0.05). HFOV reduced pulmonary blood flow (Qp) during ambient air breathing (0.33 +/- 0.11 vs. 0.28 +/- 0.09 l . kg-1 . min-1, CMV vs. HFOV, P less than 0.05) and during hypoxic gas breathing (0.38 +/- 0.11 vs. 0.29 +/- 0.09 l . kg-1 . min-1, P less than 0.05). There was no significant difference in calculated venous admixture for sulfur hexafluoride or in the index of low ventilation-perfusion lung regions with HFOV compared with CMV.(ABSTRACT TRUNCATED AT 250 WORDS)
This article has been cited by other articles:
![]() |
Y. Imai, S. Nakagawa, Y. Ito, T. Kawano, A. S. Slutsky, and K. Miyasaka Comparison of lung protection strategies using conventional and high-frequency oscillatory ventilation J Appl Physiol, October 1, 2001; 91(4): 1836 - 1844. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Sukumar, M. Bommaraju, J. E. Fisher, F. C. Morin III, M. C. Papo, B. P. Fuhrman, L. J. Hernan, and C. L. Leach High-frequency partial liquid ventilation in respiratory distress syndrome: hemodynamics and gas exchange J Appl Physiol, January 1, 1998; 84(1): 327 - 334. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |