Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 59: 509-514, 1985;
8750-7587/85 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smaldone, G. C.
Right arrow Articles by Messina, M. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smaldone, G. C.
Right arrow Articles by Messina, M. S.

Journal of Applied Physiology, Vol 59, Issue 2 509-514, Copyright © 1985 by American Physiological Society


ARTICLES

Enhancement of particle deposition by flow-limiting segments in humans

G. C. Smaldone and M. S. Messina

Severe chronic obstructive pulmonary disease is associated with central deposition of inhaled aerosols. This pattern may be due to functional narrowing of the large airways during expiration at flow-limiting segments (FLS). Using a gamma camera and 2.5-micron particles, we compared the pattern of aerosol deposition following quiet breathing with that after a controlled forced expiration (cough) when FLS are known to form in central airways. Lung size measurement by 133Xe allowed construction of regions of interest over the central airways and lung periphery. Deposition in these regions was normalized for area and lung thickness and expressed as a central-to-peripheral (C/P) ratio. In addition, using right-angle light scattering, the fraction of inhaled particles deposited with each breath (DF) was determined. During control studies, airflow and tidal volume were continuously monitored to insure that tidal loops were well below the maximum expiratory flow-volume (MEFV) curve. To create dynamic compression, cough was used to generate a partial MEFV curve, while inspiratory flow, tidal volume, and functional residual capacity were maintained close to quiet breathing.With cough, C/P ratios increased markedly from 1.04 +/- 0.18 to 2.21 +/- 0.61 (P less than 0.01, n = 6). DF for the lung and airways did not significantly change (0.43 +/- 0.11 to 0.45 +/- 0.09, P = NS). The greater enhancement of regional deposition in the central airways with deposition unchanged over the whole lung demonstrates that, during cough, peripheral deposition is actually reduced when compared with quiet breathing. We conclude that dynamic compression at FLS can be an important factor in the central deposition of inhaled particles.


This article has been cited by other articles:


Home page
ChestHome page
S. W. Stites, G. V. Perry, T. Peddicord, G. Cox, C. McMillan, and B. Becker
Effect of High-Frequency Chest Wall Oscillation on the Central and Peripheral Distribution of Aerosolized Diethylene Triamine Penta-acetic Acid as Compared to Standard Chest Physiotherapy in Cystic Fibrosis
Chest, March 1, 2006; 129(3): 712 - 717.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. Pellegrino, A. Biggi, A. Papaleo, G. Camuzzini, J. R. Rodarte, and V. Brusasco
Regional expiratory flow limitation studied with Technegas in asthma
J Appl Physiol, November 1, 2001; 91(5): 2190 - 2198.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. D. Bennett, G. Scheuch, K. L. Zeman, J. S. Brown, C. Kim, J. Heyder, and W. Stahlhofen
Bronchial airway deposition and retention of particles in inhaled boluses: effect of anatomic dead space
J Appl Physiol, August 1, 1998; 85(2): 685 - 694.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online