Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 59: 376-383, 1985;
8750-7587/85 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wagner, P. D.
Right arrow Articles by Gale, G. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wagner, P. D.
Right arrow Articles by Gale, G. E.

Journal of Applied Physiology, Vol 59, Issue 2 376-383, Copyright © 1985 by American Physiological Society


ARTICLES

Estimation of ventilation-perfusion inequality by inert gas elimination without arterial sampling

P. D. Wagner, C. M. Smith, N. J. Davies, R. D. McEvoy and G. E. Gale

Estimation of ventilation-perfusion (VA/Q) inequality by the multiple inert gas elimination technique requires knowledge of arterial, mixed venous, and mixed expired concentrations of six gases. Until now, arterial concentrations have been directly measured and mixed venous levels either measured or calculated by mass balance if cardiac output was known. Because potential applications of the method involve measurements over several days, we wished to determine whether inert gas levels in peripheral venous blood ever reached those in arterial blood, thus providing an essentially noninvasive approach to measuring VA/Q mismatch that could be frequently repeated. In 10 outpatients with chronic obstructive pulmonary disease, we compared radial artery (Pa) and peripheral vein (Pven) levels of the six gases over a 90-min period of infusion of the gases into a contralateral forearm vein. We found Pven reached 90% of Pa by approximately 50 min and 95% of Pa by 90 min. More importantly, the coefficient of variation at 50 min was approximately 10% and at 90 min 5%, demonstrating acceptable intersubject agreement by 90 min. Since cardiac output is not available without arterial access, we also examined the consequences of assuming values for this variable in calculating mixed venous levels. We conclude that VA/Q features of considerable clinical interest can be reliably identified by this essentially noninvasive approach under resting conditions stable over a period of 1.5 h.


This article has been cited by other articles:


Home page
J. Physiol.Home page
I. M. Olfert, J. Balouch, A. Kleinsasser, A. Knapp, H. Wagner, P. D. Wagner, and S. R. Hopkins
Does gender affect human pulmonary gas exchange during exercise?
J. Physiol., June 1, 2004; 557(2): 529 - 541.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS