Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 59: 262-265, 1985;
8750-7587/85 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Harf, A.
Right arrow Articles by Chang, H. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Harf, A.
Right arrow Articles by Chang, H. K.

Journal of Applied Physiology, Vol 59, Issue 1 262-265, Copyright © 1985 by American Physiological Society


ARTICLES

Respiratory resistance in dogs by the single-breath and the forced oscillation methods

A. Harf, M. Decramer, W. Zin, J. Milic-Emili and H. K. Chang

Total respiratory resistance (Rrs) was measured in six anesthetized dogs with two different methods: the single-breath (SB) method, which provides the time constant of the system during a relaxed expiration and the forced oscillation (FO) method, which uses a pseudorandom noise signal applied at the airway opening. The comparison was made in three conditions: before muscle paralysis (A), after muscle paralysis (B), and after tracheal banding (C). In conditions A and B the two computed resistances correlated very well with each other (r = 0.98). No systematic difference between Rrs values obtained with the two methods was found. In condition C the respiratory resistance was clearly nonlinear from the flow-volume curves during SB and could be described with Rohrer's equation: Rrs = K1 X V + K2 X V2, where K1 and K2 are Kohrer's constant and V is flow. Rrs measured with FO was not frequency dependent during tracheal banding (C) and was virtually equivalent to K1. Since the FO method uses low flows as the input of the respiratory system and K1 could be ascribed to laminar flow, the numerical matching appears reasonable and tends to reinforce the validity of both methods of measurement. We conclude that, for the normal respiratory system, FO and SB methods are approximately equivalent. In the presence of a markedly alinear central airway resistance with normal lungs, the SB method appears to provide a more adequate description of the flow-resistive properties of the system.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
F. ZERAH-LANCNER, F. LOFASO, A. COSTE, F. RICOLFI, F. GOLDENBERG, and A. HARF
Pulmonary Function in Obese Snorers with or without Sleep Apnea Syndrome
Am. J. Respir. Crit. Care Med., July 1, 1997; 156(2): 522 - 527.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online