Journal of Applied Physiology AJP: Endocrinology and Metabolism
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 58: 2054-2061, 1985;
8750-7587/85 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Aubier, M.
Right arrow Articles by Pariente, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Aubier, M.
Right arrow Articles by Pariente, R.

Journal of Applied Physiology, Vol 58, Issue 6 2054-2061, Copyright © 1985 by American Physiological Society


ARTICLES

Effects of hypocalcemia on diaphragmatic strength generation

M. Aubier, N. Viires, J. Piquet, D. Murciano, F. Blanchet, C. Marty, R. Gherardi and R. Pariente

We studied the effects of hypocalcemia on diaphragmatic force and diaphragm blood flow (Qdi) in 12 anesthetized dogs. The diaphragm was electrically stimulated with intramuscular electrodes surgically implanted in the ventral surface of each hemidiaphragm. The transdiaphragmatic pressure (Pdi) during supramaximal (50 V) 2-s stimulations applied over a frequency range of 10-100 Hz was measured with balloon catheters during tracheal occlusion at functional residual capacity. A catheter was placed via the femoral vein into the left inferior phrenic vein, and Qdi was measured by timed volume collections of left inferior venous effluent. A catheter was introduced in a femoral artery to monitor blood pressure (BP). In five additional dogs, the force generated by the sartorius muscle during electrical stimulation was also studied concomitantly to diaphragmatic force. The animals were mechanically ventilated throughout the experiment, and the arterial blood gases and pH were maintained constant. Hypocalcemia was induced by a continuous infusion of EGTA (70 mg X kg-1 X h-1), which led to a progressive decrease (P less than 0.0001) of ionized calcium plasmatic level from 2.21 +/- 0.4 meq/1 during control to 1.69 +/- 0.06, 1.25 +/- 0.5, and 1.07 +/- 0.5 meq/1 after 30, 60, and 120 min, respectively. Hypocalcemia decreased progressively Pdi, which amounted to 84 +/- 3 (P less than 0.001) and 98 +/- 2% of control values for the low frequencies (10 and 20 Hz) and the high frequencies (50 and 100 Hz), respectively, after 30 min of EGTA infusion and to 74 +/- 5 and 79 +/- 6% for the low and high frequencies, respectively, after 120 min.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
ChestHome page
N. R. MacIntyre
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support : A Collective Task Force Facilitated by the American College of Chest Physicians; the American Association for Respiratory Care; and the American College of Critical Care Medicine
Chest, December 1, 2001; 120 (2009): 375S - 396S.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
G. A. Schmidt and J. B. Hall
Acute on Chronic Respiratory Failure: Assessment and Management of Patients With COPD in the Emergent Setting
JAMA, June 16, 1989; 261(23): 3444 - 3453.
[Abstract] [PDF]


Home page
J Intensive Care MedHome page
D. O. Wilson and R. M. Rogers
The Role of Nutrition in Weaning from Mechanical Ventilation
J Intensive Care Med, May 1, 1989; 4(3): 124 - 133.
[Abstract] [PDF]


Home page
J Intensive Care MedHome page
M. L. Morganroth and C. M. Grum
Weaning from Mechanical Ventilation
J Intensive Care Med, March 1, 1988; 3(2): 109 - 120.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online