Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 58: 1225-1230, 1985;
8750-7587/85 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gelman, S.
Right arrow Articles by Smith, L. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gelman, S.
Right arrow Articles by Smith, L. R.

Journal of Applied Physiology, Vol 58, Issue 4 1225-1230, Copyright © 1985 by American Physiological Society


ARTICLES

Cardiac output distribution and regional blood flow during hypocarbia in monkeys

S. Gelman, K. C. Fowler, S. P. Bishop and L. R. Smith

Cardiac output distribution and regional blood flow were studied during hypocarbia independent of changes in ventilatory parameters. Fifteen cynomolgus monkeys were anesthetized with methohexital sodium (8 mg/kg im) and hyperventilated through an endotracheal tube. Hypocarbia at two levels, 28 +/- 1.8 and 17 +/- 0.6 Torr, was achieved by a stepwise decreasing CO2 flow into the semiclosed system. Regional blood flow was determined with labeled microspheres. At each stage of experiments two sets of microspheres (9 and 15 microns diam) were used simultaneously. The use of two microsphere sizes allowed evaluation of the relationship between total (nutritive and nonnutritive) tissue blood flow, determined with 15-microns spheres, and nutritive blood flow, determined with 9-microns spheres. There was no change in cardiac output or arterial pressure during both degrees of studied hypocarbia. Hypocarbia was accompanied by a decrease in myocardial blood flow determined with 15-microns spheres and preservation of the flow determined with 9-microns spheres. Splenic blood flow was decreased, whereas hepatic arterial blood flow was increased during both levels of hypocarbia. Blood flow through the brain, renal cortex, and gut showed a biphasic response to hypocarbia: during hypocarbia at 28 +/- 1.8 Torr, blood flow determined with 15-microns spheres was unchanged (in the gut) or decreased (in the brain and kidneys), whereas blood flow determined with 9-microns spheres was decreased. During hypocarbia at 17 +/- 0.6 Torr, blood flow determined with 9-microns spheres had a tendency to restore to base-line values.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Br J AnaesthHome page
S. H. Cray, M. W. Crawford, N. Khayyam, and F. J. L. Carmichael
Effects of hypoxia and isoflurane on liver blood flow: the role of adenosine
Br. J. Anaesth., March 1, 2001; 86(3): 425 - 427.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online