Journal of Applied Physiology AJP: Heart and Circulatory Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 58: 1034-1039, 1985;
8750-7587/85 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gronlund, J.
Right arrow Articles by Christensen, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gronlund, J.
Right arrow Articles by Christensen, P.

Journal of Applied Physiology, Vol 58, Issue 3 1034-1039, Copyright © 1985 by American Physiological Society


ARTICLES

Error due to dead-space admixture in single-breath method for estimation of pulmonary blood flow

J. Gronlund and P. Christensen

The single-breath method of Kim et al. (J. Appl. Physiol. 21: 1338-1344, 1966) for the estimation of pulmonary blood flow is based on a single-alveolus lung model for which an analytical relationship has been established between the kinetic behavior of the alveolar O2 and CO2 tensions and the pulmonary blood flow. The analysis is based on the assumption that the dead-space contribution to the expirate is negligible after expiration of a predefined volume. We have examined the influence of this assumption on the estimation of pulmonary blood flow by computer simulation in a lung model that incorporates deadspace contribution to the expirate. Data on the fractional contribution of the dead space to the expired gas were obtained from Tsunoda et al.'s study (J. Appl. Physiol. 32: 644-649, 1972) on the emptying pattern of normal adult lungs. The results show that failure to take account of the dead-space contribution can cause an underestimation in the pulmonary blood flow of greater than 30%. The error can be reduced by ignoring the first part of the expiration but only at the cost of an increase in the sensitivity of the single-breath method to measurement noise. This property of the system is demonstrated experimentally. The error due to dead-space admixture depends on the total volume of dead-space gas, the measurement noise, the pulmonary blood flow, and the emptying characteristics of the dead-space compartment during expiration. In normal subjects it is possible to optimize the experimental design so that the systematic error is less than 5% and the coefficient of variation is less than 10%.(ABSTRACT TRUNCATED AT 250 WORDS)





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online