Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 58: 223-229, 1985;
8750-7587/85 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wilson, F. J.
Right arrow Articles by Bone, R. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wilson, F. J., Jr
Right arrow Articles by Bone, R. C.

Journal of Applied Physiology, Vol 58, Issue 1 223-229, Copyright © 1985 by American Physiological Society


ARTICLES

Quantitative deposition of ultrafine stable particles in the human respiratory tract

F. J. Wilson Jr, F. C. Hiller, J. D. Wilson and R. C. Bone

Theoretical models of particle deposition in the respiratory tract predict high fractional deposition for particles of less than 0.1 micron, but there are few confirming experimental data for those predictions. We have measured the deposition fraction of a nonhygroscopic aerosol in the human respiratory tract. The aerosol had a count mean diameter of 0.044 micron SD of 1.93, as measured with an electrical aerosol analyzer, and was produced from a 0.01% solution of bis(2-ethylhexyl) sebacate using a condensation generator. Subjects inhaled the aerosol using a controlled respiratory pattern of 1 liter tidal volume, 12/min. Deposition was calculated as the difference in concentration between inhaled and exhaled aerosol of five size fractions corrected for system deposition and dead-space constants. Three deposition studies were done on each of five normal male volunteers. Means (+/- SE) for the five size fractions were 0.024 micron, 0.71 +/- 0.06; 0.043 micron, 0.62 +/- 0.06; 0.075 micron, 0.53 +/- 0.05; 0.13 micron, 0.44 +/- 0.04; and 0.24 micron, 0.37 +/- 0.06. These data demonstrate that deposition of inhaled particles in the 0.024- to 0.24-micron size range is high and increases with decreasing size. These observations agree with and validate predictions of mathematical models.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
J. S. Brown, K. L. Zeman, and W. D. Bennett
Ultrafine Particle Deposition and Clearance in the Healthy and Obstructed Lung
Am. J. Respir. Crit. Care Med., November 1, 2002; 166(9): 1240 - 1247.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
H J Bunn, D Dinsdale, T Smith, and J Grigg
Ultrafine particles in alveolar macrophages from normal children
Thorax, December 1, 2001; 56(12): 932 - 934.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online