Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 58: 105-113, 1985;
8750-7587/85 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Oldmixon, E. H.
Right arrow Articles by Hoppin, F. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Oldmixon, E. H.
Right arrow Articles by Hoppin, F. G., Jr

Journal of Applied Physiology, Vol 58, Issue 1 105-113, Copyright © 1985 by American Physiological Society


ARTICLES

Perfusion dehydration fixes elastin and preserves lung air-space dimensions

E. H. Oldmixon, S. Suzuki, J. P. Butler and F. G. Hoppin Jr

We sought a technique to preserve lung tissue for micrography with air-space dimensions unchanged from the fresh state. In our hands, conventional techniques were problematical. Aware of the possibility that distortion might be caused by inadequate mechanical fixation of elastin, we dehydrated the still-inflated lung by intravascular perfusion with graded ethanols. Canine and rabbit lungs so prepared had straighter alveolar septa, greater air-space dimensions, and an improved correlation with light-scattering measurements. Bovine ligamentum nuchae (mostly elastin) was only partially fixed by glutaraldehyde or osmium tetroxide but was effectively stiffened by dehydration. We conclude that perfusion dehydration aids in the faithful preservation of parenchymal configuration, probably by mechanical fixation of elastin.


This article has been cited by other articles:


Home page
ERRHome page
C. C. W. Hsia
Quantitative morphology of compensatory lung growth
Eur. Respir. Rev., December 1, 2006; 15(101): 148 - 156.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Lung Cell. Mol. Physiol.Home page
X. Yan, J. J. Polo Carbayo, E. R. Weibel, and C. C. W. Hsia
Variation of lung volume after fixation when measured by immersion or Cavalieri method
Am J Physiol Lung Cell Mol Physiol, January 1, 2003; 284(1): L242 - L245.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. P. Butler, R. E. Brown, D. Stamenovic, J. P. Morris, and G. P. Topulos
Effect of surface tension on alveolar surface area
J Appl Physiol, September 1, 2002; 93(3): 1015 - 1022.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Lung Cell. Mol. Physiol.Home page
C. C. W. Hsia, E. Y. Wu, E. Wagner, and E. R. Weibel
Preventing mediastinal shift after pneumonectomy impairs regenerative alveolar tissue growth
Am J Physiol Lung Cell Mol Physiol, November 1, 2001; 281(5): L1279 - L1287.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. J. Tschumperlin and S. S. Margulies
Alveolar epithelial surface area-volume relationship in isolated rat lungs
J Appl Physiol, June 1, 1999; 86(6): 2026 - 2033.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Lung Cell. Mol. Physiol.Home page
J. P. Wood, J. E. Kolassa, and J. T. McBride
Changes in alveolar septal border lengths with postnatal lung growth
Am J Physiol Lung Cell Mol Physiol, December 1, 1998; 275(6): L1157 - L1163.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online