Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 57: 1126-1133, 1984;
8750-7587/84 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kosch, P. C.
Right arrow Articles by Stark, A. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kosch, P. C.
Right arrow Articles by Stark, A. R.

Journal of Applied Physiology, Vol 57, Issue 4 1126-1133, Copyright © 1984 by American Physiological Society


ARTICLES

Dynamic maintenance of end-expiratory lung volume in full-term infants

P. C. Kosch and A. R. Stark

We recorded airflow, tidal volume, respiratory muscle electromyogram (EMG), and chest wall configuration in eight normal newborn infants to investigate the determination of end-expiratory lung volume (EEV). The expiratory flow-volume representation was nearly linear and EMG evidence of respiratory muscle activity was absent during the latter part of expiration in both supine and upright postures, consistent with passive expiration. Occasional breaths were associated with marked retardation of expiratory airflow (braking). During unobstructed apnea, expiration proceeded to the relaxation volume (Vr) with no change in slope of the flow-volume curve. During breathing, EEV was greater than Vr observed during apnea. We calculated the difference between EEV and Vr estimated by extrapolation of the linear portion of the expiratory flow-volume curve as 14.4 +/- 5.4 ml (supine) and 11.8 +/- 2.4 ml (upright). When infants were tilted from supine to upright, expiratory duration (TE) and the expiratory time constant (tau) increased significantly. Since the increases in tau and TE offset each other, the EEV-Vr difference was similar in both postures. We propose that while braking plays a major role in the early part of expiration, as long as the final portion of expiration is passive, the dynamic maintenance of EEV above Vr depends on the relative values of tau and TE. Expiratory braking mechanisms interact with the passive mechanical properties of the respiratory system to modulate the balance between tau and TE. These mechanisms provide a neonatal breathing strategy to maintain EEV above a low Vr until the chest wall stiffens with maturity.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
M. L. Siew, M. J. Wallace, M. J. Kitchen, R. A. Lewis, A. Fouras, A. B. te Pas, N. Yagi, K. Uesugi, K. K. W. Siu, and S. B. Hooper
Inspiration regulates the rate and temporal pattern of lung liquid clearance and lung aeration at birth
J Appl Physiol, June 1, 2009; 106(6): 1888 - 1895.
[Abstract] [Full Text] [PDF]


Home page
JSLHRHome page
K. J. Reilly and C. A. Moore
Respiratory Movement Patterns During Vocalizations at 7 and 11 Months of Age
J Speech Lang Hear Res, February 1, 2009; 52(1): 223 - 239.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. N. Baldwin, B. Suki, J. J. Pillow, H. L. Roiha, S. Minocchieri, and U. Frey
Effect of sighs on breathing memory and dynamics in healthy infants
J Appl Physiol, November 1, 2004; 97(5): 1830 - 1839.
[Abstract] [Full Text] [PDF]


Home page
J Intensive Care MedHome page
S. Davis, A. C. Cox, M. Piedmonte, J. J. Drummond-Webb, R. B. B. Mee, and A. M. Harrison
Prolonged Mechanical Ventilation after Cardiac Surgery in Young Children: Incidence, Etiology, and Risk Factors
J Intensive Care Med, November 1, 2002; 17(6): 302 - 307.
[Abstract] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement on Respiratory Muscle Testing
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. Hassan, J. Gossage, D. Ingram, S. Lee, and A. D. Milner
Volume of activation of the Hering-Breuer inflation reflex in the newborn infant
J Appl Physiol, March 1, 2001; 90(3): 763 - 769.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G. Schmalisch, B. Foitzik, R.R. Wauer, and J. Stocks
Effect of apparatus dead space on breathing parameters in newborns: "flow-through" versus conventional techniques
Eur. Respir. J., January 1, 2001; 17(1): 108 - 114.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
X. Zhang and E. N. Bruce
Correlation structure of end-expiratory lung volume in anesthetized rats with intact upper airway
Am J Physiol Regulatory Integrative Comp Physiol, June 1, 2000; 278(6): R1446 - R1452.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
C. Morley
Continuous distending pressure
Arch. Dis. Child. Fetal Neonatal Ed., September 1, 1999; 81(2): 152F - 156.
[Full Text]


Home page
J. Appl. Physiol.Home page
K. Brown, J. Stocks, C. Aun, and P. S. Rabbette
The Hering-Breuer reflex in anesthetized infants: end-inspiratory vs. end-expiratory occlusion technique
J Appl Physiol, April 1, 1998; 84(4): 1437 - 1446.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online