Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 57: 1069-1078, 1984;
8750-7587/84 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Simon, B. A.
Right arrow Articles by Mitzner, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Simon, B. A.
Right arrow Articles by Mitzner, W.

Journal of Applied Physiology, Vol 57, Issue 4 1069-1078, Copyright © 1984 by American Physiological Society


ARTICLES

Mean airway pressure and alveolar pressure during high-frequency ventilation

B. A. Simon, G. G. Weinmann and W. Mitzner

Studies and applications of high-frequency ventilation (HFV) are often performed under conditions of controlled mean airway pressure (Paw). In the present study we tested the assumption that controlling Paw adequately controls lung volume during HFV by investigating the relationship between a reliably measured Paw and the mean alveolar pressure (Palv) of the lungs during HFV of healthy dogs. We minimized the errors of Paw measurement due to the Bernoulli effect and various technical factors by appropriate choice of transducers, amplifiers, and measurement site. Palv was estimated by clamping the ventilator tube during oscillation and measuring the equilibration pressure of the lung and airways. Paw and Palv were determined as functions of frequency (8-25 Hz), tidal volume (60-90 ml), Paw (-5 to 12 cmH2O), and position of the animal (supine vs. lateral). We found that Paw could significantly underestimate Palv and that the degree of underestimation increased at higher frequencies, larger tidal volumes, and lower Paw. Shifting the animal from the supine to the lateral position greatly accentuated this effect. The elevation of Palv above Paw was seen to be a function of mean flow and largely independent of the frequency-tidal volume combination which produced the flow. A possible explanation of this pressure difference is that it results from differences in inspiratory and expiratory airway impedances, which in turn depend on airway geometry, compliance, lung volume, and expiratory flow limitation.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
J. J. Pillow, H. Neil, M. H. Wilkinson, and C. A. Ramsden
Effect of I/E ratio on mean alveolar pressure during high-frequency oscillatory ventilation
J Appl Physiol, July 1, 1999; 87(1): 407 - 414.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
U. Thome and F. Pohlandt
Effect of the TI/TE ratio on mean intratracheal pressure in high-frequency oscillatory ventilation
J Appl Physiol, May 1, 1998; 84(5): 1520 - 1527.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. A. Simon, K. Tsuzaki, and J. G. Venegas
Changes in regional lung mechanics and ventilation distribution after unilateral pulmonary artery occlusion
J Appl Physiol, March 1, 1997; 82(3): 882 - 891.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online