Journal of Applied Physiology Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 57: 888-891, 1984;
8750-7587/84 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Muza, S. R.
Right arrow Articles by Zechman, F. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Muza, S. R.
Right arrow Articles by Zechman, F. W.

Journal of Applied Physiology, Vol 57, Issue 3 888-891, Copyright © 1984 by American Physiological Society


ARTICLES

Scaling of added loads to breathing: magnitude estimation vs. handgrip matching

S. R. Muza and F. W. Zechman

Six healthy male adults were studied at five levels of suprathreshold added resistance (delta R) applied three times to inspiration in a random sequence. Subjects squeezed an isometric handgrip dynamometer coincident with the breath to express the perceived magnitude of the load and also gave a numerical estimate after completing the loaded inspiration. Peak mouth pressure, grip deflection, and numerical estimate were analyzed to derive the exponents for Stevens' power law. The mean exponent and correlation coefficient obtained from numerical estimates were 1.11 +/- 0.16 and 0.94 +/- 0.04, respectively, while the exponent and correlation coefficient simultaneously obtained from handgrip matching was 0.73 +/- 0.10 and 0.91 +/- 0.05, respectively. Multiplying each subject's exponent obtained from handgrip matching by 1.7 yields a mean equated exponent of 1.23 +/- 0.17. The equated exponents were not statistically different (P greater than 0.05) from the exponents derived from numerical estimates. These results suggest that the use of cross-modality (handgrip) matching provides a reliable method for obtaining psychophysical magnitude functions of respiratory sensations and that exponents obtained using either technique can be equated for comparison.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
N. K. Burki, W. J. Dale, and L.-Y. Lee
Intravenous adenosine and dyspnea in humans
J Appl Physiol, January 1, 2005; 98(1): 180 - 185.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. Zhao, A. D. Martin, and P. W. Davenport
Magnitude estimation of inspiratory resistive loads by double-lung transplant recipients
J Appl Physiol, February 1, 2003; 94(2): 576 - 582.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. A. Daubenspeck, H. L. Manning, and J. C. Baird
Midlatency respiratory-related somatosensory activity and perception of oral pressure pulses in normal humans
J Appl Physiol, June 1, 2001; 90(6): 2048 - 2056.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online