Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 57: 14-20, 1984;
8750-7587/84 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zwart, A.
Right arrow Articles by Zijlstra, W. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zwart, A.
Right arrow Articles by Zijlstra, W. G.

Journal of Applied Physiology, Vol 57, Issue 1 14-20, Copyright © 1984 by American Physiological Society


ARTICLES

Human whole-blood oxygen affinity: effect of carbon monoxide

A. Zwart, G. Kwant, B. Oeseburg and W. G. Zijlstra

Oxygen dissociation curves (ODC) were recorded in the presence of carboxyhemoglobin fractions (FHbCO) up to 60%. The gradual shift to the left of the ODC at increasing amounts of HbCO was reflected in a gradual fall in the half-saturation pressure of the remaining Hb and was accompanied by a gradual change in the shape of the ODC to a hyperbolic one. The H+ factor (delta log PO2/delta pH) was determined over the entire oxygen saturation (SO2) range at three different FHbCO levels (14, 30, and 52%). At FHbCO = 14 and 30% and for the SO2 range 20-90%, the H+ factor vs. SO2 curve was not significantly different from that in the absence of HbCO. At FHbCO = 52%, however, the value found for the H+ factor (-0.55) was appreciably more negative than in the case of blood containing less than 1% HbCO (-0.44), and there was no dependence on SO2. Comparison of measured and calculated ODCs at varying HbCO fractions showed, for FHbCO less than or equal to 50%, that measured and calculated ODCs coincide over the greater part of the SO2 range. For FHbCO greater than 50%, the measured ODC was situated to the left of the calculated one over the entire SO2 range. We conclude that the heme-heme interaction for CO is appreciably larger than for O2 only for FHbCO greater than 50%, whereas for FHbCO less than 50% there is virtually no difference.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
J. Toffaletti and W. G. Zijlstra
Misconceptions in Reporting Oxygen Saturation
Anesth. Analg., December 1, 2007; 105(6S_Suppl): S5 - S9.
[Abstract] [Full Text] [PDF]


Home page
Indoor and Built EnvironmentHome page
Y. I. Baris, J. A. Hoskins, Z. Seyfikli, and A. Demir
'Biomass Lung': Primitive Biomass Combustion and Lung Disease
Indoor and Built Environment, November 1, 2002; 11(6): 351 - 358.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online