|
|
||||||||
Journal of Applied Physiology, Vol 56, Issue 6 1666-1669, Copyright © 1984 by American Physiological Society
ARTICLES |
S. A. Silbaugh and J. L. Mauderly
Tidal volume measured by the barometric method is very sensitive to increases in compression and expansion of alveolar gas, such as would be expected to occur during airway narrowing or closure. By comparing a barometric method tidal volume signal (VT') with a reference tidal volume (VT) obtained with a head-out pressure plethysmograph, a simple index related to gas compressibility effects was calculated (VT/VT'). Changes in this index were compared with decreases in dynamic compliance (Cdyn) during histamine aerosol challenge of 15 Charles River Hartley guinea pigs. Decreases in VT/VT' occurred during all aerosol challenges and were correlated with decreases in Cdyn (r = 0.84, P less than 0.001). Decreases in VT/VT' were most marked at Cdyn values of less than 50% of base line. At Cdyn of less than 15% of base line, VT' was 3.1-4.8 times the VT reference signal. No increase in total pulmonary resistance was noted, and Cdyn and VT/VT' returned to base line after histamine exposure was stopped. We conclude that gas compressibility effects become substantial during histamine-induced airway constriction in the guinea pig and that the VT/VT' ratio appears to provide a simple noninvasive method of detecting these changes.
This article has been cited by other articles:
![]() |
A. Adler, G. Cieslewicz, and C. G. Irvin Unrestrained plethysmography is an unreliable measure of airway responsiveness in BALB/c and C57BL/6 mice J Appl Physiol, July 1, 2004; 97(1): 286 - 292. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. T. Bates and C. G. Irvin Measuring lung function in mice: the phenotyping uncertainty principle J Appl Physiol, April 1, 2003; 94(4): 1297 - 1306. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. K. A. Lundblad, C. G. Irvin, A. Adler, and J. H. T. Bates A reevaluation of the validity of unrestrained plethysmography in mice J Appl Physiol, October 1, 2002; 93(4): 1198 - 1207. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Hoffman, H. Kuehn, K. Riedelberger, R. Kupcinskas, and M. B. Miskovic Flowmetric comparison of respiratory inductance plethysmography and pneumotachography in horses J Appl Physiol, December 1, 2001; 91(6): 2767 - 2775. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. HAMELMANN, J. SCHWARZE, K. TAKEDA, A. OSHIBA, G. L. LARSEN, C. G. IRVIN, and E. W. GELFAND Noninvasive Measurement of Airway Responsiveness in Allergic Mice Using Barometric Plethysmography Am. J. Respir. Crit. Care Med., September 1, 1997; 156(3): 766 - 775. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |