Journal of Applied Physiology Add DOIs to your references at manuscript stage!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 56: 708-715, 1984;
8750-7587/84 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rubin, D. Z.
Right arrow Articles by Mittman, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rubin, D. Z.
Right arrow Articles by Mittman, C.

Journal of Applied Physiology, Vol 56, Issue 3 708-715, Copyright © 1984 by American Physiological Society


ARTICLES

Factors affecting expired waveform for carbon monoxide

D. Z. Rubin, S. M. Lewis and C. Mittman

We previously presented a method based on a computer lung model for determining the distribution of both specific ventilation and specific diffusing capacity. These argon and carbon monoxide (CO) washin and washout studies were obtained in 12 normal subjects and 24 patients with varying degrees of obstructive lung disease. In addition to end-tidal and mixed expired gas concentrations, the expired waveform for both gases was sampled. In patients we found that this method failed to adequately describe CO dynamics during the early part of expiration; predicted concentrations were higher than actual data. Modifications of the original model that satisfy all data are presented. This new model suggests that CO uptake occurs in spaces with ventilatory properties of dead space. The accuracy and reliability of these observations were established by computer simulation studies as well as by repeated testing in one subject. These proved to be highly reproducible over a period of 5 mo. Standard parameter sensitivity tests showed parameters to vary by less than 10% and to be stable even when realistic levels of noise were added to the data. We conclude that studies involving ventilation of insoluble gases are insufficient to describe gas exchange in the lung. The addition of an exchangeable gas adds significant understanding of lung function, particularly in disease.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online