Journal of Applied Physiology AJP: Advances in Physiology Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 56: 196-201, 1984;
8750-7587/84 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sampson, M. G.
Right arrow Articles by Smaldone, G. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sampson, M. G.
Right arrow Articles by Smaldone, G. C.

Journal of Applied Physiology, Vol 56, Issue 1 196-201, Copyright © 1984 by American Physiological Society


ARTICLES

Voluntary induced alterations in regional ventilation in normal humans

M. G. Sampson and G. C. Smaldone

We tested the hypothesis that voluntary changes of thoraco-abdominal shape can influence regional ventilation via altering regional pleural pressure swings (Ppl). Regional ventilation was measured simultaneously with regional Ppl during tidal volume breathing maneuvers in five normal subjects while they were performing one of three thoracoabdominal patterns of breathing: normal, preferential intercostal (IC), or preferential diaphragmatic (DIA). In every subject, the lower lung region's 133Xe washout rate was faster than the upper region's, regardless of the pattern of thoracoabdominal breathing adopted. Although IC breathing tended to make regional ventilation more homogeneous, DIA breathing tended to augment regional ventilation inhomogenities. On the average, the Ppl values were greatest in the lower lung region, regardless of the thoracoabdominal pattern adopted; however, IC breathing reduced and DIA breathing increased regional Ppl inhomogenities. When the ratios of the Ppl (lower/upper) were plotted vs. the ratios of the regional 133Xe washout decay constants (lower/upper), a significant positive correlation was found. These data suggest that a causal relation between regional tidal Ppl and regional ventilation exist, thus supporting the concept that thoracoabdominal shape changes can influence regional ventilation.


This article has been cited by other articles:


Home page
Br J AnaesthHome page
I. Galvin, G. B. Drummond, and M. Nirmalan
Distribution of blood flow and ventilation in the lung: gravity is not the only factor
Br. J. Anaesth., April 1, 2007; 98(4): 420 - 428.