Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 56: 155-160, 1984;
8750-7587/84 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Harf, A.
Right arrow Articles by Chang, H. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Harf, A.
Right arrow Articles by Chang, H. K.

Journal of Applied Physiology, Vol 56, Issue 1 155-160, Copyright © 1984 by American Physiological Society


ARTICLES

Ventilation by high-frequency oscillation of thorax or at trachea in rats

A. Harf, C. Bertrand and H. K. Chang

The efficiency of ventilation by high-frequency oscillation (HFO) applied to the thorax (external HFO) has been compared with that of HFO applied through a tracheal cannula (internal HFO) in a group of normal rats. Anesthetized, paralyzed, tracheotomized rats were placed in a whole-body plethysmograph. External HFO was achieved by varying the pressure surrounding the animal by means of a piston pump connected to the body plethysmograph; internal HFO was obtained in the same animals by connecting the pump to the tracheal cannula. Arterial CO2 and O2 partial pressures were measured in blood sampled from a carotid artery and were compared for external and internal HFO applied at 20 Hz with matched tidal volumes of 0.8, 1.4, 1.9, and 2.4 ml/kg. With increasing tidal volume, the mean arterial CO2 partial pressure decreased progressively from 68 to 30 Torr and was identical in the two modes of HFO; no difference was noted for the CO2 elimination or for the arterial O2 partial pressure. These results indicate that, in terms of gas exchange, external and internal HFO are equally efficient in normal rats.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
K. Kolandaivelu and C.-S. Poon
A miniature mechanical ventilator for newborn mice
J Appl Physiol, February 1, 1998; 84(2): 733 - 739.