Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 55: 1784-1789, 1983;
8750-7587/83 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rodenstein, D. O.
Right arrow Articles by Stanescu, D. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rodenstein, D. O.
Right arrow Articles by Stanescu, D. C.

Journal of Applied Physiology, Vol 55, Issue 6 1784-1789, Copyright © 1983 by American Physiological Society


ARTICLES

Airway closure in humans does not result in overestimation of plethysmographic lung volume

D. O. Rodenstein, C. Francis and D. C. Stanescu

Exercise Physiol. 52: 638-641, 1982) have shown in dogs that airway closure may induce rib cage deformation and nonhomogeneous alveolar pressure swings, and they have suggested that this could lead to thoracic gas volume (TGV) overestimation by body plethysmography. However, in humans the rib cage is less easy to distort than in dogs. In four healthy volunteers we measured TGV by plethysmography before (B) and during (D) the occlusion of the middle and lower right lobes by a balloon (attached to a double-lumen catheter) positioned in the intermediate right bronchus. Subjects were trained to perform panting maneuvers preferentially with intercostals and accessory muscles or the diaphragm. Five to eleven TGV measurements were made in each subject with each panting pattern B and D occlusion. Balloon inflation resulted in no change in TGV whether low [13.3 +/- 3.4 (SD) cmH2O] or high (46.8 +/- 8.4 cmH2O) transdiaphragmatic pressures (Pdi) were used: TGV 4.0 +/- 0.4 (B) vs. 4.0 +/- 0.4 liters (D) and 4.3 +/- 0.4 (B) vs. 4.3 +/- 0.4 liters (D) for low and high Pdi, respectively. Thus, in trained subjects performing maneuvers aimed to distort the rib cage, no pressure difference was observed between the occluded and the nonoccluded lung during panting against the closed shutter. We conclude that it is unlikely that the mechanism proposed by Brown et al. might explain errors in lung volume measurements by body plethysmography in humans.