Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 55: 935-948, 1983;
8750-7587/83 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hoffman, E. A.
Right arrow Articles by Wood, E. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hoffman, E. A.
Right arrow Articles by Wood, E. H.

Journal of Applied Physiology, Vol 55, Issue 3 935-948, Copyright © 1983 by American Physiological Society


ARTICLES

Estimation of regional pleural surface expansile forces in intact dogs

E. A. Hoffman, T. Behrenbeck, P. A. Chevalier and E. H. Wood

Distances between percutaneously inserted apical and basal lung markers determined by biplane X-ray, computer-based videometry (J. Appl. Physiol. 34: 544, 1973) were calibrated against dependent percutaneously recorded pleural liquid pressures (J. Appl. Physiol. 31: 277, 1971) in five 10-12 kg mongrel dogs under morphine-pentobarbital anesthesia studied without thoracotomy. At the same apical pleural-liquid pressure values, the apical intermarker distances were uniformly greater when in the head-up rather than head-down position. This finding suggests that the expansile forces acting on the apical regions of the lung, in the head-up position, are greater (-30 +/- 2 cmH2O) than would be predicted from "pleural liquid" pressures (-15 +/- 1 cmH2O) measured at this nondependent site in the thorax, and much greater than the "pleural surface" pressures measured by the generally accepted balloon and counter-pressure techniques. In contrast, in the head-down body position, expansile forces acting on the nondependent basal regions of the lung estimated by the intermarker distance technique were variable to either side of the pressures measured by open-ended liquid-filled catheters, and thus were not significantly different. Mean values measured by the catheters and predicted by the markers were -14 +/- 1 and -10 +/- 3 cmH2O, respectively.


This article has been cited by other articles:


Home page
Proc Am Thorac SocHome page
E. A. Hoffman, B. A. Simon, and G. McLennan
State of the Art. A Structural and Functional Assessment of the Lung via Multidetector-Row Computed Tomography: Phenotyping Chronic Obstructive Pulmonary Disease
Proceedings of the ATS, August 1, 2006; 3(6): 519 - 532.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online