|
|
||||||||
Journal of Applied Physiology, Vol 55, Issue 3 1015-1022, Copyright © 1983 by American Physiological Society
ARTICLES |
J. H. Bates, G. K. Prisk, T. E. Tanner and A. E. McKinnon
Mass spectrometers produce distorted measurements of gas concentrations because of the time delays and rise times inherent in their responses. Three techniques for numerically correcting such distortion were applied to the acetylene step responses of a Perkin-Elmer MGA1100 mass spectrometer and to simulated data. The techniques investigated were 1) a simple time-delay correction, 2) an exponential model method that assumes a biexponential form for the peak of the impulse response, and 3) a Fourier transform method of deconvolution known as Wiener filtering. The time-delay correction produced an order of magnitude reduction in measurement error. The exponential model method improved on the time-delay correction, and the Wiener filter gave the most accurate corrections in all cases examined.
This article has been cited by other articles:
![]() |
G. K. Prisk, J. M. Fine, T. K. Cooper, and J. B. West Vital capacity, respiratory muscle strength, and pulmonary gas exchange during long-duration exposure to microgravity J Appl Physiol, August 1, 2006; 101(2): 439 - 447. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. K. Prisk, J. M. Fine, T. K. Cooper, and J. B. West Pulmonary gas exchange is not impaired 24 h after extravehicular activity J Appl Physiol, December 1, 2005; 99(6): 2233 - 2238. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Montmerle, P. Sundblad, and D. Linnarsson Residual heterogeneity of intra- and interregional pulmonary perfusion in short-term microgravity J Appl Physiol, June 1, 2005; 98(6): 2268 - 2277. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Rohdin, J. Petersson, M. Mure, R. W. Glenny, S. G. E. Lindahl, and D. Linnarsson Distributions of lung ventilation and perfusion in prone and supine humans exposed to hypergravity J Appl Physiol, August 1, 2004; 97(2): 675 - 682. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Rohdin, J. Petersson, P. Sundblad, M. Mure, R. W. Glenny, S. G. E. Lindahl, and D. Linnarsson Effects of gravity on lung diffusing capacity and cardiac output in prone and supine humans J Appl Physiol, July 1, 2003; 95(1): 3 - 10. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. D. Farmery and C. E. W. Hahn A method of reconstruction of clinical gas-analyzer signals corrupted by positive-pressure ventilation J Appl Physiol, April 1, 2001; 90(4): 1282 - 1290. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. D. Farmery and C. E. W. Hahn Response-time enhancement of a clinical gas analyzer facilitates measurement of breath-by-breath gas exchange J Appl Physiol, August 1, 2000; 89(2): 581 - 589. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |