Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 55: 578-582, 1983;
8750-7587/83 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Giezendanner, D.
Right arrow Articles by Cerretelli, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Giezendanner, D.
Right arrow Articles by Cerretelli, P.

Journal of Applied Physiology, Vol 55, Issue 2 578-582, Copyright © 1983 by American Physiological Society


ARTICLES

A programmable electrically braked ergometer

D. Giezendanner, P. E. Di Prampero and P. Cerretelli

Research protocols require that the actual braking power (Wb) of electrically braked ergometers (EBE) is precisely set at the chosen power level, stable, and universally programmable. No commercially available EBEs appear to meet jointly the above conditions. In fact, EBE settings were found to deviate up to 25% from the reference level (WR), their Wb to drop as a result of increased temperature as much as 30% within 1 h of continuous operation, and the programming features to be limited and rigid. To overcome the above pitfalls a procedure for building or improving EBEs is presented whereby 1) the stator of the brake used as a dynamometer is mounted on ball bearings, the torque being transmitted to a strain gauge; 2) the number of revolutions of the rotor is measured on a cogwheel by a proximity detector and an impulse counter; and 3) the torque and impulse number signals are fed into a low-priced microcomputer controlling the brake's power supply. The device has proved to be satisfactory in following any preprogrammed exercise-forcing functions. In the range approximately 10-500 W, Wb = WR +/- 1%.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
P. K. JEFFERY
The Development of Large and Small Airways
Am. J. Respir. Crit. Care Med., May 1, 1997; 157(5): 174 - 180.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online