Journal of Applied Physiology Information on EB 2010
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 54: 956-960, 1983;
8750-7587/83 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Olson, L. E.
Right arrow Articles by Robinson, N. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Olson, L. E.
Right arrow Articles by Robinson, N. E.

Journal of Applied Physiology, Vol 54, Issue 4 956-960, Copyright © 1983 by American Physiological Society


ARTICLES

Pressure-flow relationships in a collaterally ventilating dog lung segment

L. E. Olson, J. R. Rodarte and N. E. Robinson

We evaluated the pressure (P)-flow (V) relationship in collaterally ventilating dog lung segments by passing He, N2, and SF6 through a bronchoscope (5 mm OD) wedged in a peripheral airway. Measurements were made at functional residual capacity (FRC) and two higher lung volumes, keeping segment-to-airway opening pressure constant (3 cmH2O) in five anesthetized, paralyzed, vagotomized, supine dogs. Average flows ranged from 5.0 to 8.0 ml/s for He, 4.5 to 7.5 ml/s for N2, and 3.4 to 4.7 ml/s for SF6. When these data were fitted as P = K1/3/3 mu V + K2 rho V2, density-dependent pressure losses were unimportant when He and N2 were used, suggesting laminar flow with these gases. A dimensionless plot of the total pressure drop relative to a reference dynamic pressure as a function of Reynolds number at the bronchoscope tip suggested that flow through the segment behaved as if it were laminar at Reynolds numbers less than 100. Furthermore, when the airway diameter used to compute the normalized pressure and Reynolds number was scaled as the cubic root of lung volume, curves for all three gases were superimposed, suggesting that the dimensions of intrasegmental/collateral airways scale as lung volume 1/3.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
Z. Hantos, F. Petak, A. Adamicza, T. Asztalos, J. Tolnai, and J. J. Fredberg
Mechanical impedance of the lung periphery
J Appl Physiol, November 1, 1997; 83(5): 1595 - 1601.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online