Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 54: 609-618, 1983;
8750-7587/83 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Engel, L. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Engel, L. A.

Journal of Applied Physiology, Vol 54, Issue 3 609-618, Copyright © 1983 by American Physiological Society


ARTICLES

Gas mixing within the acinus of the lung

L. A. Engel

The subject is reviewed with an emphasis on recent developments in model analyses. Application of computer technology has facilitated the study of simultaneous convection and diffusion within a complex geometry approximating the airways and air spaces of the lung. During an inspiration of fresh gas the diffusion front separating inspired from "alveolar" gas is stationed within a portion of the acinus where the magnitudes of gas transport by convection and diffusion are similar. This constitutes the peripheral boundary of the Fowler dead space. Asymmetry of intra-acinar branching results in an inequality of gas concentrations within alveolar gas, despite homogeneous volume expansion. This is due to an interaction between diffusion and convection at branch points subtending units of unequal lengths. During a respiratory cycle a "diffusive Pendelluft" between these units results in a "first in-first out" pattern and a sloping alveolar plateau on the expired tracing, despite synchronous and homogeneous volume changes. Experimental results suggest that incomplete alveolar gas mixing constitutes a measurable limitation to gas exchange in the normal lung.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
G. Tusman, M. Areta, C. Climente, R. Plit, F. Suarez-Sipmann, M. J. Rodriguez-Nieto, G. Peces-Barba, E. Turchetto, and S. H. Bohm
Effect of pulmonary perfusion on the slopes of single-breath test of CO2
J Appl Physiol, August 1, 2005; 99(2): 650 - 655.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
G. Tusman, S. H. Bohm, F. S. Sipmann, and S. Maisch
Lung Recruitment Improves the Efficiency of Ventilation and Gas Exchange During One-Lung Ventilation Anesthesia
Anesth. Analg., June 1, 2004; 98(6): 1604 - 1609.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Gronkvist, E. Bergsten, O. Eiken, and P. M. Gustafsson
Inter- and intraregional ventilation inhomogeneity in hypergravity and after pressurization of an anti-G suit
J Appl Physiol, April 1, 2003; 94(4): 1353 - 1364.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Gronkvist, E. Bergsten, and P. M. Gustafsson
Effects of body posture and tidal volume on inter- and intraregional ventilation distribution in healthy men
J Appl Physiol, February 1, 2002; 92(2): 634 - 642.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
O. HJALMARSON and K. SANDBERG
Abnormal Lung Function in Healthy Preterm Infants
Am. J. Respir. Crit. Care Med., January 1, 2002; 165(1): 83 - 87.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. A. Altemeier, S. McKinney, and R. W. Glenny
Fractal nature of regional ventilation distribution
J Appl Physiol, May 1, 2000; 88(5): 1551 - 1557.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online