Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 53: 1175-1183, 1982;
8750-7587/82 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Castile, R.
Right arrow Articles by Stokes, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Castile, R.
Right arrow Articles by Stokes, D.

Journal of Applied Physiology, Vol 53, Issue 5 1175-1183, Copyright © 1982 by American Physiological Society


ARTICLES

Effects of posture on flow-volume curve configuration in normal humans

R. Castile, J. Mead, A. Jackson, M. E. Wohl and D. Stokes

Tien et al. (J. Appl. Physiol.: Respirat. Environ. Exercise Physiol. 46: 565-570, 1979) found reproducible details in the configuration of averaged maximal expiratory flow-volume curves and suggested that these details may correspond to sudden relocations of airway choke points. The occurrence of choke points depends on factors affecting local airway pressure-diameter behavior. We postulated that changes in posture as they affect the distribution of lung recoil on airways might change the locations of choke points and thereby alter flow-volume configuration. Twenty normal adults performed five flow-volume curves in each of four postures (standing, supine, right, and left lateral recumbent). Volume was measured with a Krogh spirometer and airflow with a Fleisch No. 4 pneumotachometer. Curves were digitally filtered and plotted relative to upright total lung capacity. Five curves in each posture were averaged at increments of 0.1 l/s of flow and average volumes at given flows were compared using the Student's t test. Significant differences (P less than 0.01) in mean volumes at given flows occurred in all subjects from standing to supine and/or right to left lateral postures. Large changes in configuration were apparent in one of the two postural pairs in eight subjects. We conclude that changes in posture result in significant changes in flow-volume configuration in most normal adults. These findings are consistent with the wave-speed theory of flow limitation and suggest that small changes in local airway stresses can significantly alter the location and motion of airway choke points during forced expiration.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
T. G. Babb, D. S. DeLorey, B. L. Wyrick, and P. P. Gardner
Mild obesity does not limit change in end-expiratory lung volume during cycling in young women
J Appl Physiol, June 1, 2002; 92(6): 2483 - 2490.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
L. Eltayara, H. Ghezzo, and J. Milic-Emili
Orthopnea and Tidal Expiratory Flow Limitation in Patients With Stable COPD
Chest, January 1, 2001; 119(1): 99 - 104.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. K. Prisk
Physiology of a Microgravity Environment: Invited Review: Microgravity and the lung
J Appl Physiol, July 1, 2000; 89(1): 385 - 396.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online