Journal of Applied Physiology Add DOIs to your references at manuscript stage!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 53: 1125-1132, 1982;
8750-7587/82 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Braslow, N. M.
Right arrow Articles by Kazemi, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Braslow, N. M.
Right arrow Articles by Kazemi, H.

Journal of Applied Physiology, Vol 53, Issue 5 1125-1132, Copyright © 1982 by American Physiological Society


ARTICLES

Noninvasive cardiac output determination using inhaled oxygen-15-labeled carbon dioxide

N. M. Braslow, C. A. Hales, B. Hoop, D. J. Kanarek and H. Kazemi

Inhaled oxygen-15-labeled carbon dioxide (CO2*) is hydrated in the alveolar capillary blood to produce oxygen-15-labeled water (H2O*). This allows noninvasive delivery of a traceable indicator into the pulmonary circulation. Removal of oxygen-15 marker from the lung is a function of pulmonary perfusion. Two techniques were evaluated for computing cardiac output (CO) following single bolus inhalation of CO2*: 1) continuous monitoring of arterial blood activity through an external detector and 2) noninvasive positron imaging of oxygen-15-label washout from the chest and simultaneous emergence of activity in arterial blood. In seven mongrel dogs studied using technique 1, 46 determinations of CO were made from 1.2 to 8.0 l/min and compared with simultaneous indocyanine green dye-dilution determination. Correlation coefficient was 0.90 with slope of linear regression of 1.05. In 12 mongrel dogs studied using technique 2, 23 determinations of CO were made from 0.9 to 9.2 l/min and compared with simultaneous indocyanine green dye determination. Correlation coefficient was 0.985 (P less than 0.001) with slope of linear regression of 0.898. This noninvasive technique (2) for determination of CO is independent of assumptions regarding regional ventilation or perfusion of the lung and appears valid in animal studies.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online