Journal of Applied Physiology Information on EB 2010
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 53: 567-575, 1982;
8750-7587/82 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Inoue, H.
Right arrow Articles by Hildebrandt, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Inoue, H.
Right arrow Articles by Hildebrandt, J.

Journal of Applied Physiology, Vol 53, Issue 3 567-575, Copyright © 1982 by American Physiological Society


ARTICLES

Temperature effects on lung mechanics in air- and liquid-filled rabbit lungs

H. Inoue, C. Inoue and J. Hildebrandt

Effects of temperature on lung pressure-volume (PV) curves and on the reversibility of changes were studied in the range of 4-52 degrees C. Air curves were obtained first at 21 degrees C, then after 60 min equilibration at one of seven test temperatures (4, 21, 32, 37, 42, 47, and 52 degrees C) and finally again at 21 degrees C. In a given lung, peak inflation volume was made identical at all temperatures. Warming from 4 to 42 degrees C steadily diminished both inflation and deflation pressures, but thereafter the trend reversed except on the upper part of the inflation curve. On returning to 21 degrees C, all PV curves were indistinguishable except from 52 degrees C. Liquid PV curves were obtained in a similar way at four temperatures (4, 21, 37, and 52 degrees C). Warming from 4 to 52 degrees C diminished tissue elastic recoil at total lung capacity (TLC) from 17 to 5 cmH2O but raised recoil slightly at lower lung volumes. Liquid PV curves were also reversible except after 52 degrees C. At 37 degrees C the estimated tissue component of the total recoil of air-filled lungs exceeded 95% at 40-60% TLC, and at 21 degrees was 85-90%. This fraction fell to 50% or less at 4 and 52 degrees C, where surface forces failed to reach low levels and alveolar instability resulted.


This article has been cited by other articles:


Home page
Integr. Comp. Biol.Home page
S. Orgeig, W. Bernhard, S. C. Biswas, C. B. Daniels, S. B. Hall, S. K. Hetz, C. J. Lang, J. N. Maina, A. K. Panda, J. Perez-Gil, et al.
The anatomy, physics, and physiology of gas exchange surfaces: is there a universal function for pulmonary surfactant in animal respiratory structures?
Integr. Comp. Biol., October 1, 2007; 47(4): 610 - 627.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. Yan, S. C. Biswas, T. G. Laderas, and S. B. Hall
The melting of pulmonary surfactant monolayers
J Appl Physiol, May 1, 2007; 102(5): 1739 - 1745.
[Abstract] [Full Text] [PDF]


Home page
J. Biol. Chem.Home page
J. Bernardino de la Serna, J. Perez-Gil, A. C. Simonsen, and L. A. Bagatolli
Cholesterol Rules: DIRECT OBSERVATION OF THE COEXISTENCE OF TWO FLUID PHASES IN NATIVE PULMONARY SURFACTANT MEMBRANES AT PHYSIOLOGICAL TEMPERATURES
J. Biol. Chem., September 24, 2004; 279(39): 40715 - 40722.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
P. R. M. ROCCO, E. M. NEGRI, P. M. KURTZ, F. P. VASCONCELLOS, G. H. SILVA, V. L. CAPELOZZI, P. V. ROMERO, and W. A. ZIN
Lung Tissue Mechanics and Extracellular Matrix Remodeling in Acute Lung Injury
Am. J. Respir. Crit. Care Med., September 15, 2001; 164(6): 1067 - 1071.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online