Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 52: 786-791, 1982;
8750-7587/82 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsoi, C. M.
Right arrow Articles by Westenskow, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsoi, C. M.
Right arrow Articles by Westenskow, D. R.

Journal of Applied Physiology, Vol 52, Issue 3 786-791, Copyright © 1982 by American Physiological Society


ARTICLES

Instrumentation simultaneously measuring VCO2 and VO2 in humans using titration methods

C. M. Tsoi, D. B. Raemer and D. R. Westenskow

An instrument has been developed for the simultaneous measurement of carbon dioxide excretion (VCO2) and oxygen uptake (VO2). This instrument, the Nutrimeter, gives these breath-averaged measurements continuously without having to determine respiratory flow rate, perform timed spirometric gas collections, or determine absolute CO2 or O2 concentrations. It can be used on ventilated or nonventilated patients in long- and short-term studies. VO2 is determined via the replenishment technique. VCO2 is determined via a new technique, absorption-titration, described here. Bench test results of VCO2 measurements show a standard error of the estimate (SEE) +/- 0.591% of full scale (500 ml/min) and maximum single point error (MSPE) of +/- 3.54% over a 100--350 ml/min range. VO2 measurements show SEE +/- 0.518% of full scale (1,000 ml/min) and MSPE +/- 2.42% over a 100--450 ml/min range. In 31 human clinical trials the Nutrimeter was compared with the open-circuit spirometric collection and micro-Scholander analysis technique. VCO2 measurements show SEE +/- 2.208% and MSPE +/- 10.57% over 135--315 ml/min. VO2 measurements show SEE +/- 1.134% of full scale and MSPE +/- 9.54% over 170--360 ml/min. Response time is 60 s optimally for step changes in VO2 (0--90% of steady-state value), 90 s for VCO2.