Journal of Applied Physiology http://www.adinstruments.com/labchart/faseb
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 52: 79-84, 1982;
8750-7587/82 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Noguchi, H.
Right arrow Articles by Yamabayashi, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Noguchi, H.
Right arrow Articles by Yamabayashi, H.

Journal of Applied Physiology, Vol 52, Issue 1 79-84, Copyright © 1982 by American Physiological Society


ARTICLES

Breath-by-breath VCO2 and VO2 required compensation for transport delay and dynamic response

H. Noguchi, Y. Ogushi, I. Yoshiya, N. Itakura and H. Yamabayashi

Both transport delay (DELAY) and dynamic response (RESPONSE) of a mass spectrometer would theoretically result in considerable errors in the breath-by-breath calculation of VCO2 and VO2. However, curiously, the contribution of RESPONSE has been ignored. The purpose of this study is to quantify the error caused by RESPONSE. We found that RESPONSE of a mass spectrometer was regarded as a first-order response. We determined DELAY and time constant (T) of RESPONSE and compensated the on-line calculation for both DELAY and RESPONSE and for DELAY only. With T of 150 and 100 ms, deviations of VCO2 from the gas-collection method were 8 +/- 6 and 8 +/- 6 ml/min with compensation for both DELAY and RESPONSE, and 69 +/- 10 and 50 +/- 5 ml/min with compensation for DELAY only, respectively (mean +/- SD). Similar results were obtained with VO2. A computer simulation of error caused by RESPONSE disclosed that the error linearly increased with increasing T. We conclude that to be accurate within +/- 5% of the exact value, compensation should be made when T exceeds 25 ms.


This article has been cited by other articles:


Home page
ChestHome page
S. Miyoshi, T. Yoshimasu, T. Hirai, I. Hirai, S. Maebeya, T. Bessho, and Y. Naito
Exercise Capacity of Thoracotomy Patients in the Early Postoperative Period
Chest, August 1, 2000; 118(2): 384 - 390.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
Y. Sekine, Y. Miyata, K. Yamada, H. Yamada, T. Yasukawa, Y. Saitoh, S. Yoshida, and T. Fujisawa
Video-assisted thoracoscopic surgery does not deteriorate postoperative pulmonary gas exchange in spontaneous pneumothorax patients
Eur. J. Cardiothorac. Surg., July 1, 1999; 16(1): 48 - 53.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
Y. Masaoka and I. Homma
Expiratory time determined by individual anxiety levels in humans
J Appl Physiol, April 1, 1999; 86(4): 1329 - 1336.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS