Journal of Applied Physiology Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 52: 260-266, 1982;
8750-7587/82 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Urmey, W. F.
Right arrow Articles by Song, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Urmey, W. F.
Right arrow Articles by Song, P.

Journal of Applied Physiology, Vol 52, Issue 1 260-266, Copyright © 1982 by American Physiological Society


ARTICLES

Effect of interstitial fluid (kerosene) on pressure-volume characteristics of rat lung

W. F. Urmey, S. M. Scharf, R. Brown, D. Carlson and P. Song

Although pulmonary interstitial edema has been estimated to decrease pulmonary compliance (CL), it has been experimentally difficult to demonstrate whether the observed changes in CL are directly due to the presence of interstitial fluid or if they result instead from concomitant pulmonary vascular engorgement and/or alveolar edema. Since kerosene-inflated lungs do not leak, we were able to use kerosene to measure the effect on CL of the accumulation of interstitial fluid (kerosene) in the postmortem rat lung. Pressure-volume (PV) studies of the lung were done during the progressive increase in interstitial fluid (kerosene). Analysis of the deflation limbs of the quasistatic PV curves obtained following serial inflations with kerosene indicated that the maximal volume of kerosene [MV35, equal to the maximum tissue plus airway volume at a transpulmonary pressure (Ptp) of 35 cmH2O] was 3.8 +/- 1.2 ml (31.0 +/- 11.8%) greater than TLC35 [air volume at Ptp of 35 cmH2O prior to kerosene inflation]. The increases in interstitial kerosene volume had no effect on kerosene PV characteristics, as was demonstrated by superimposing lung PV curves obtained at various states of interstitial filling. We conclude that the interstitial compartment is large and very compliant and that the presence of even great amounts of fluid limited to this compartment does not restrict lung expansion.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online