Journal of Applied Physiology AJP citation statistics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 51: 1375-1383, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Overland, E. S.
Right arrow Articles by Murray, J. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Overland, E. S.
Right arrow Articles by Murray, J. F.

Journal of Applied Physiology, Vol 51, Issue 6 1375-1383, Copyright © 1981 by American Physiological Society


ARTICLES

Measurement of pulmonary tissue volume and blood flow in persons with normal and edematous lungs

E. S. Overland, R. N. Gupta, G. J. Huchon and J. F. Murray

We measured pulmonary tissue volume (Vt) and pulmonary capillary blood flow (Qc) by a rebreathing method using two soluble gases, acetylene (C2H2) and dimethyl ether (DME), in 32 normal subjects and 14 patients who had had pulmonary edema. In 18 of the normal subjects, studies were performed at three or more different rebreathing volumes (VA). To normalize for differences in body size, results were expressed as the ratio of Vt or VA to predicted total lung capacity (TLC). We found that 1) changes in VA/TLC had a significant effect on Vt/TLC and Qc measured with both gases, 2) the range of normal values for Vt was best defined by expressing the relationship between Vt/TLC and VA/TLC, 3) using this approach, many patients with clinically mild or inapparent pulmonary edema had abnormal values of Vt, and 4) when comparing mean values of C2H2 and DME in 82 simultaneous measurements at constant VA/TLC, Vt was significantly higher in 87% (71/82) and Qc in 63% (52/82) of the paired tests.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
S. Verbanck, H. Larsson, D. Linnarsson, G. K. Prisk, J. B. West, and M. Paiva
Pulmonary tissue volume, cardiac output, and diffusing capacity in sustained microgravity
J Appl Physiol, September 1, 1997; 83(3): 810 - 816.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online