Journal of Applied Physiology AJP: Cell Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 51: 1338-1348, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Isabey, D.
Right arrow Articles by Chang, H. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Isabey, D.
Right arrow Articles by Chang, H. K.

Journal of Applied Physiology, Vol 51, Issue 5 1338-1348, Copyright © 1981 by American Physiological Society


ARTICLES

Steady and unsteady pressure-flow relationships in central airways

D. Isabey and H. K. Chang

We measured pressure-flow relationships in a noncompliant five-generation cast of human central airways using air, HeO2, and SF6O2 at 0, 0.25, 0.50, 1.0, and 2.0 Hz with tidal volumes of 0.25, 0.5, and 1.0 liter. When dimensionless pressure drops for steady inspiratory and expiratory flows of the various gas mixture were plotted against Reynolds' number on a log-log scale (Moody diagram), they formed two curves as fluid mechanical theory predicts. At frequencies higher than 0.25 Hz, data obtained from 1) the same gas and same stroke volume, 2) the same frequency and same stroke volume but different gases, and 3) the same gas at the same frequency but with different stroke volumes, all deviated from the steady flow curves in the Moody diagram, always tending to increase the dimensionless pressure drop. The increase was largest when instantaneous flow was near zero and was minimal at the peak flow in a given inspiration or expiration. These data led to the identification of a dimensionless parameter (epsilon) that reflects the relative importance of local acceleration (unsteadiness) to convective acceleration at any given instant during a flow cycle. A dimensional analysis then reveals that the pressure-flow relationship in a given airway system is uniquely and completely determined by a combination of three dimensionless parameters: Reynolds number (Re), Womersley number (alpha), and the new parameter (epsilon). With this set of parameters we can explain all reported apparent paradoxes as well as the present findings.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
S. JABER, R. FODIL, A. CARLUCCI, M. BOUSSARSAR, J. PIGEOT, F. LEMAIRE, A. HARF, F. LOFASO, D. ISABEY, and L. BROCHARD
Noninvasive Ventilation with Helium-Oxygen in Acute Exacerbations of Chronic Obstructive Pulmonary Disease
Am. J. Respir. Crit. Care Med., April 1, 2000; 161(4): 1191 - 1200.
[Abstract] [Full Text]


Home page
J. Appl. Physiol.Home page
P.-H. Jarreau, B. Louis, G. Dassieu, L. Desfrere, P. W. Blanchard, G. Moriette, D. Isabey, and A. Harf
Estimation of inspiratory pressure drop in neonatal and pediatric endotracheal tubes
J Appl Physiol, July 1, 1999; 87(1): 36 - 46.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online