Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 51: 1038-1041, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Muller, N. L.
Right arrow Articles by Zamel, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Muller, N. L.
Right arrow Articles by Zamel, N.

Journal of Applied Physiology, Vol 51, Issue 4 1038-1041, Copyright © 1981 by American Physiological Society


ARTICLES

Pneumotachograph calibration for inspiratory and expiratory flows during HeO2 breathing

N. L. Muller and N. Zamel

Maximum expiratory flows during breathing of a 80% helium-20% oxygen mixture (HeO2) are commonly used to determine the site of airflow limitation. To do this test the flowmeter is usually calibrated with the inspired gases, and the airflows are measured during expiration. We tested the adequacy of such calibration maneuvers by using two identical flowmeters in series through a bag-in-box system. Different gases were flowed though the test pneumotachograph into a bag contained in a closed box connected to the second pneumotachograph. Distension of the bag caused air to flow from the box through this second pneumotachograph. Our results indicate that when breathing HeO2, the flowmeter correction for different gas viscosity, compared with air, should be 20% for inspired HeO2 and 12% for expired gases. Inspired gases therefore cannot be used to calibrate the flowmeters when assessing expiratory flows.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
L. de Rochefort, L. Vial, R. Fodil, X. Maitre, B. Louis, D. Isabey, G. Caillibotte, M. Thiriet, J. Bittoun, E. Durand, et al.
In vitro validation of computational fluid dynamic simulation in human proximal airways with hyperpolarized 3He magnetic resonance phase-contrast velocimetry
J Appl Physiol, May 1, 2007; 102(5): 2012 - 2023.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. Pecchiari, A. Pelucchi, E. D'Angelo, A. Foresi, J. Milic-Emili, and E. D'Angelo
Effect of Heliox Breathing on Dynamic Hyperinflation in COPD Patients
Chest, June 1, 2004; 125(6): 2075 - 2082.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J. P. Kress, I. Noth, B. K. Gehlbach, N. Barman, A. S. Pohlman, A. Miller, S. Morgan, and J. B. Hall
The Utility of Albuterol Nebulized with Heliox during Acute Asthma Exacerbations
Am. J. Respir. Crit. Care Med., May 1, 2002; 165(9): 1317 - 1321.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
S. JABER, R. FODIL, A. CARLUCCI, M. BOUSSARSAR, J. PIGEOT, F. LEMAIRE, A. HARF, F. LOFASO, D. ISABEY, and L. BROCHARD
Noninvasive Ventilation with Helium-Oxygen in Acute Exacerbations of Chronic Obstructive Pulmonary Disease
Am. J. Respir. Crit. Care Med., April 1, 2000; 161(4): 1191 - 1200.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online