Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 51: 524-528, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hills, B. A.
Right arrow Articles by Butler, B. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hills, B. A.
Right arrow Articles by Butler, B. D.

Journal of Applied Physiology, Vol 51, Issue 2 524-528, Copyright © 1981 by American Physiological Society


ARTICLES

A method of producing calibrated microtubules for air embolism studies

B. A. Hills and B. D. Butler

Utilizing the differential absorption techniques in conjunction with gas injection methods has enabled the production of calibrated microtubules with diameters ranging from 14 to 300 micron. Nitrogen was blended with CO2, the "diluent" gas, to produce the initial bubbles, while tris(hydroxymethyl)-aminomethane hydrochloride (THAM) was used as an absorbent to remove the diluent gas from the bubbles. Hence, the diameters of the initial bubbles were significantly reduced with only the inert gas remaining. The Coulter counter was used for immediate size monitoring of the microtubules. To verify the inertness of the absorbent medium, nine anesthetized dogs were infused with increasing amounts of the solution. In five of the animals plasma surface tension and pH (arterial) were measured, while in the remaining four arterial blood pressure, heart rate, breathing frequency, and pulmonary artery pressure was measured before, during, and after the injections. Changes in plasma surface tension and pH were minimal while acceptable physiological values were recorded, all of which were in agreement with previous investigations. Differential absorption techniques provided a reliable means for producing calibrated micro-bubbles for air embolism studies.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online