Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 51: 516-519, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baun, W. B.
Right arrow Articles by Raven, P. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baun, W. B.
Right arrow Articles by Raven, P. B.

Journal of Applied Physiology, Vol 51, Issue 2 516-519, Copyright © 1981 by American Physiological Society


ARTICLES

Comparison of heart rate measurement protocols used during autonomic function tests

W. B. Baun, A. Jackson, R. W. Patton and P. B. Raven

The five most used cold pressor test heart rate protocols were compared to the true R-R interval responses recorded during a cold hand test. Forty-one nonsmoking male volunteers between 18 and 55 yr were given a cold hand pressor test. Heart rate was evaluated by averaging the R-R interval within 2-, 5-, 6-, 10-, and 30-s time intervals and by the true R-R interval measurement. No significant physiological differences existed at rest; however, during stress the maximum values obtained were successively diminished the greater the time utilized to average the heart rate pressure (P less than 0.05). During recovery an underestimation of the true response was observed that increased as the averaging time increased (P less than 0.05). Comparison between the R-R interval measure and the 6-s average data indicated a 18% decrease in the time of peak response. Therefore, the responses recorded with the 6-s averaged data were less sensitive and obscured the rapidity of autonomic changes. Hence, when sensitivity and absolute response are a primary concern in determining autonomic function, measurements should include R-R interval measures of heart rate or the average of the number of R-R intervals in 2-s time blocks.