Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 51: 321-326, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Klassen, T.
Right arrow Articles by Berend, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Klassen, T.
Right arrow Articles by Berend, N.

Journal of Applied Physiology, Vol 51, Issue 2 321-326, Copyright © 1981 by American Physiological Society


ARTICLES

Correlation between lung structure and function in a canine model of emphysema

T. Klassen, W. M. Thurlbeck and N. Berend

To correlate lung structure and function in an animal model of emphysema, 17 dog lungs were treated with intrabronchial instillation of papain (range of concentration 0.5-5%); the contralateral lungs served as controls. The lungs were inflated to the volume at a transpulmonary pressure (PL) of 25 cmH2O (V25), and static pressure-volume and maximal expiratory flow-volume curves were obtained. Eight pairs of lungs were processed for histology at a PL of 5 cmH2O, and eight pairs of lungs were processed at a PL of 25 cmH2O. Significant loss of elastic recoil was found in the papain-treated lungs, between 30 and 90% predicted V25 (P less than 0.02). However, there was no correlation between the mean linear intercept corrected to predicted lung volume (indicative of alveolar destruction) and loss of elastic recoil. There was a significant reduction of maximal flow (Vmax) between 20 and 90% predicted V25. However, the reduction in Vmax was commensurate with the reduction of elastic recoil, since there was no significant change in resistance of the upstream segment between 30 and 70% predicted V25. Airway morphometry demonstrated no significant differences in small airway dimensions between control and emphysema-treated lungs. In both control and papain-treated lungs, small airway dimensions changed relatively more than lung volume a PL of 25 and 5 cmH2O.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. K. Lambert and P. D. Pare
Lung parenchymal shear modulus, airway wall remodeling, and bronchial hyperresponsiveness
J Appl Physiol, July 1, 1997; 83(1): 140 - 147.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. M. Barnas, P. A. Delaney, I. Gheorghiu, S. Mandava, R. G. Russell, R. Kahn, and C. F. Mackenzie
Respiratory impedances and acinar gas transfer in a canine model for emphysema
J Appl Physiol, July 1, 1997; 83(1): 179 - 188.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online