Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 50: 1318-1324, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suratt, P. M.
Right arrow Articles by Rochester, D. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suratt, P. M.
Right arrow Articles by Rochester, D. F.

Journal of Applied Physiology, Vol 50, Issue 6 1318-1324, Copyright © 1981 by American Physiological Society


ARTICLES

Lung compliance and its transient elevations measured with pulse-flow method

P. M. Suratt, D. H. Owens, H. Hsiao, D. L. Kaiser and D. F. Rochester

We describe a pulse-flow method of measuring static lung compliance (CL) that is sensitive to rapid transients in CL. CL is measured by blowing air at a constant flow into the mouth and lungs for 2 s and calculated by dividing airflow in 1/s by the change in transpulmonary pressure in CMH2O/s. Pulse and static inspiratory CL was measured in five normals, four obstructives, five obese, and two patients with pulmonary fibrosis, Pulse CL after tidal breathing was correlated with static CL measured after deep breaths (r = 0.96). Pulse CL after deep breaths was higher than pulse CL after tidal breathing (p less than 0.01) and then static CL after deep breaths (p less than 0.05). In all subjects the lower the forced expiratory volume in 1 s, expressed as a percentage of vital capacity (FEV1/FVC), the greater the increase in pulse CL after a deep breath will be (r = 0.93). After deep breaths pulse CL fell from maximum CL to base-line CL at a rate related to 1/t2 where t equals the time in seconds from the last deep breath. We conclude that the increase in CL after a deep breath is related to the degree of airway obstruction and that the subsequent fall in CL is related to 1/t2.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online