Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 50: 1104-1110, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sinnett, E. E.
Right arrow Articles by Butler, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sinnett, E. E.
Right arrow Articles by Butler, J. P.

Journal of Applied Physiology, Vol 50, Issue 5 1104-1110, Copyright © 1981 by American Physiological Society


ARTICLES

Fast integrated flow plethysmograph for small mammals

E. E. Sinnett, A. C. Jackson, D. E. Leith and J. P. Butler

The accurate measurement of a forced vital capacity (FVC) maneuver in a small mammal requires that the plethysmograph in use have good response characteristics at high frequencies. We develop, on a theoretical basis, the behavior of zeroth-order (pressure type), first-order (flow type without inertance), and second-order (flow type with inertance) plethysmogrphs. The actual frequency response of a mouse-sized plethysmograph is then presented, and a technique for improving its response characteristics is described. A flat amplitude response (within 3% of a reference flow taken as truth) was obtained for sinusoidal inputs below 240 Hz. A phase lag with respect to the reference flow equivalent to a simple time delay of 1.4 ms was observed up to 150 Hz. A typical FVC curve for a mouse is shown, and criteria are provided for designing similar plethysmographs suitable for use with larger animals.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
J. S. Reynolds, V. J. Johnson, and D. G. Frazer
Unrestrained acoustic plethysmograph for measuring specific airway resistance in mice
J Appl Physiol, August 1, 2008; 105(2): 711 - 717.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. L. S. Lofgren, M. R. Mazan, E. P. Ingenito, K. Lascola, M. Seavey, A. Walsh, and A. M. Hoffman
Restrained whole body plethysmography for measure of strain-specific and allergen-induced airway responsiveness in conscious mice
J Appl Physiol, November 1, 2006; 101(5): 1495 - 1505.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Cell Physiol.Home page
S. Rao and A. S. Verkman
Analysis of organ physiology in transgenic mice
Am J Physiol Cell Physiol, July 1, 2000; 279(1): C1 - C18.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online