Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 50: 1071-1078, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Luijendijk, S. C.
Right arrow Articles by de Vries, W. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Luijendijk, S. C.
Right arrow Articles by de Vries, W. R.

Journal of Applied Physiology, Vol 50, Issue 5 1071-1078, Copyright © 1981 by American Physiological Society


ARTICLES

Evaluation of alveolar amplitude response technique for determination of lung perfusion in exercise

S. C. Luijendijk, A. Zwart, A. M. van der Kooij and W. R. de Vries

We investigated the influence of tracer gas venous return on the determination of pulmonary perfusion (Qp) using the alveolar amplitude response technique (AART) to evaluate the applicability of this technique at rest and during exercise. The venous return influence was calculated by a computer simulation applied to a simplified body compartment model. Using the AART method, which neglects the influence of venous return, a simulation based on acetylene as a tracer gas predicted an overestimation of the actual value of Qp ranging from 0 to 10% for all work loads investigated. These theoretical results were compared with experimental results. Experiments with human subjects with acetylene as the tracer gas yielded an underestimation of Qp of about 20% at rest and an overestimation of about 7% under different exercise conditions. Experiments with anesthetized dogs showed an underestimation of Qp of about 12% for acetylene and about 6% for halothane. The theoretical and experimental results related to exercise conditions are thus in good quantitative agreement. The experimental data obtained for acetylene with human subjects at rest and with anesthetized dogs are also in good quantitative agreement. However, they deviate considerably from theoretical predictions. This discrepancy may be due to the simplified body compartment model used in the calculations, which can considerably influence the calculated results, especially for conditions at rest. The main conclusion of this paper is that recirculating tracer gas does not unduly influence results for Qp obtained with the AART method when halothane is used as the tracer gas.