Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 50: 829-834, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Piantadosi, C. A.
Right arrow Articles by Spaur, W. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piantadosi, C. A.
Right arrow Articles by Spaur, W. H.

Journal of Applied Physiology, Vol 50, Issue 4 829-834, Copyright © 1981 by American Physiological Society


ARTICLES

Metabolic response to respiratory heat loss-induced core cooling

C. A. Piantadosi, E. D. Thalmann and W. H. Spaur

To study the phenomenon of isolated core cooling, four resting men breathed cooled helium-oxygen (T in = 14 +/- 2 degrees C, 40-60% relative humidity) in a warm hyperbaric chamber at pressures equivalent to 640, 1,000, and 1,400, and 1,800 ft seawater (fsw). Rectal temperature (T re) fell by 0.43 +/- 0.13 degrees C at 640 fsw to 0.98 +/- 0.15 degrees C at 1,800 fsw after 60 min. The rate at which T re fell was linearly related to the product of inspired gas density times specific heat. The metabolic response (VO2) to this isolated core cooling was more closely related to the rate of fall in T re than to the magnitude of this fall. A distinct threshold temperature, below which a rise in VO2 would occur, was not demonstrable. However, when the rate of fall of T re exceeded 0.70 degrees C . h-1, VO2 increased above base line, in spite of high skin temperatures that may have blunted the VO2 response. When VO2 did increase, its net benefit on thermal homeostasis was negated by the associated rise in pulmonary ventilation and its attendant increase in respiratory heat loss. Breathing cool helium-oxygen under hyperbaric conditions can rapidly lower deep body temperature, even in the presence of a warm body surface.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online