Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 50: 552-560, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hirsch, J. A.
Right arrow Articles by Bishop, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hirsch, J. A.
Right arrow Articles by Bishop, B.

Journal of Applied Physiology, Vol 50, Issue 3 552-560, Copyright © 1981 by American Physiological Society


ARTICLES

Volume, flow, and timing of each breath during negative airway pressure in humans

J. A. Hirsch and B. Bishop

We have analyzed the effects of 4-6 min of 5, 10 and 15 cmH2O continuous negative airway pressure breathing (NPB) on steady-state end-expiratory lung volume (delta VR) and breathing pattern. Fourteen healthy adults, seated in a full body box, breathed via a mouthpiece on a bag-in-box. Pressure in the body box was elevated to the desired pressure level. Inspiratory (TI) and expiratory (TE) durations, tidal volume (VT), minute ventilation (VI), mean inspiratory flow (VT/TI), and mean expiratory flow (VT/TE) were calculated from pneumotachometer recordings. The effects of NPB are decreases in delta VR, VT, and VT/TI and increases in VT/TE. The responses to NPB are an increase in breathing frequency, due to a shortened TE, and an increase in inspiratory activity. The decrease in delta VR and the increase in VT/TE are limited by an active retardation of expiratory flow. End-tidal CO2 and VI were not altered significantly during NPB, suggesting no alveolar hyperventilation. Thus multiple components of the human response to NPB are not all engaged at the same levels of NPB. The changes in the timing of respiratory events occur at -5 cmH2O, whereas VT compensation is not seen until -15 cmH2O.


This article has been cited by other articles:


Home page
J. Neurophysiol.Home page
J.-C. Viemari, M. Bevengut, P. Coulon, and G. Hilaire
Nasal Trigeminal Inputs Release the A5 Inhibition Received by the Respiratory Rhythm Generator of the Mouse Neonate
J Neurophysiol, February 1, 2004; 91(2): 746 - 758.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online