Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 50: 259-264, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Patterson, R. W.
Right arrow Articles by Sullivan, S. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Patterson, R. W.
Right arrow Articles by Sullivan, S. F.

Journal of Applied Physiology, Vol 50, Issue 2 259-264, Copyright © 1981 by American Physiological Society


ARTICLES

Hypoxemia and pulmonary gas exchange during hemodialysis

R. W. Patterson, A. R. Nissenson, J. Miller, R. T. Smith, R. G. Narins and S. F. Sullivan

With measured values of arterial blood gas tensions, of expired respiratory gas fractions, and volume of the expired ventilation, the determinants of alveolar oxygen tension (PAO2) were used to evaluate their influence on the development of the arterial hypoxemia that occurs in spontaneously breathing patients undergoing hemodialysis using an acetate dialysate. Dialysis produced no significant changes in the alveolar-arterial O2 tension gradient (AaDO2). The extracorporeal dialyzer removed an average of 30 ml.m-2.min-1 of CO2. Accordingly the pulmonary gas exchange ratio (R) dropped from a mean predialysis value of 0.81 to 0.62 (P less than 0.001). The arterial CO2 tension remained constant throughout, whereas the minute ventilation, both total (P less than 0.01) and alveolar (P less than 0.01), decreased during dialysis. This decrease in ventilation accounts for more than 80% of the fall in PAO2. During dialysis there was a decrease (P less than 0.001) in arterial oxygen tension (PaO2), which varied among the individuals from 9 to 23% of control. During the postdialysis hour PaO2 returns to control values concomitant with increase in ventilation. The quantitative gas exchange relationships among R, alveolar ventilation, and AaDO2 predict the PaO2 values actually measured.


This article has been cited by other articles:


Home page
Nutr Clin PractHome page
H. A. Haugen, L.-N. Chan, and F. Li
Indirect Calorimetry: A Practical Guide for Clinicians
Nutr Clin Pract, August 1, 2007; 22(4): 377 - 388.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS