Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 50: 78-83, 1981;
8750-7587/81 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wolkove, N.
Right arrow Articles by Cherniack, N. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wolkove, N.
Right arrow Articles by Cherniack, N. S.

Journal of Applied Physiology, Vol 50, Issue 1 78-83, Copyright © 1981 by American Physiological Society


ARTICLES

Perception of changes in breathing in normal human subjects

N. Wolkove, M. D. Altose, S. G. Kelsen, P. G. Kondapalli and N. S. Cherniack

Respiratory sensation was evaluated in normal subjects from their ability to quantitate changes in tidal volume. Subjects attempted to duplicate or double tidal volumes of different sizes while breathing freely or against a resistive or elastic load. When the mechanical conditions during control and test breaths were constant, tidal volume duplication was accomplished with an error of approximately 100 ml, regardless of the control volume. The error in doubling, however, increased progressively with increasing control tidal volume. There was a greater error in both volume duplication and doubling when the mechanical conditions between control and test breaths were changed. When test breaths against a load followed unloaded control breaths, tidal volume failed to double, but intrathoracic pressure changes twice exceeded control values. Conversely, when unloaded test breaths followed loaded control breaths, pressure changes underwent less than a twofold increase while tidal volume more than doubled. The results indicate that tidal volume changes are normally sensed with considerable accuracy and suggest that both tidal volume per se, as well as the forces generated by the respiratory muscles, are used in the estimation of tidal volume changes.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
W. Zhao, A. D. Martin, and P. W. Davenport
Magnitude estimation of inspiratory resistive loads by double-lung transplant recipients
J Appl Physiol, February 1, 2003; 94(2): 576 - 582.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Knafelc and P. W. Davenport
Relationship between magnitude estimation of resistive loads, inspiratory pressures, and the RREP P1 peak
J Appl Physiol, August 1, 1999; 87(2): 516 - 522.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Knafelc and P. W. Davenport
Relationship between resistive loads and P1 peak of respiratory-related evoked potential
J Appl Physiol, September 1, 1997; 83(3): 918 - 926.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online