Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 49: 735-742, 1980;
8750-7587/80 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Beardsmore, C. S.
Right arrow Articles by Silverman, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beardsmore, C. S.
Right arrow Articles by Silverman, M.

Journal of Applied Physiology, Vol 49, Issue 4 735-742, Copyright © 1980 by American Physiological Society


ARTICLES

Improved esophageal balloon technique for use in infants

C. S. Beardsmore, P. Helms, J. Stocks, D. J. Hatch and M. Silverman

Esophageal balloons of three different wall thicknesses, two different lengths, and two different diameters were made to assess which type of balloon gave the most consistent and reliable measurements of dynamic compliance (CL) and pulmonary resistance (Rp). The balloons were subjected to in vitro testing to determine their pressure-volume characteristics and working range and then used in infants to compare in vivo results from one balloon to another. The optimal balloon was found to have a length of 35--50 mm, a diameter of 7.6 mm, and a wall thickness of 0.045--0.075 mm. The use of unsuitable balloons or inappropriate volumes of air within the balloon resulted in applied pressures being under-recorded, both in vitro and in vivo, with consequent overestimation of CL and underestimation of Rp during infant lung function tests. Recommendations are made concerning the techniques of making and using esophageal balloons.


This article has been cited by other articles:


Home page
PediatricsHome page
T. L. Miller, T. Cox, T. Blackson, D. Paul, K. Weiss, and T. H. Shaffer
Pulmonary Function Assessment in an Infant With Barnes Syndrome: Proactive Evaluation for Surgical Intervention
Pediatrics, October 1, 2006; 118(4): e1264 - e1267.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement on Respiratory Muscle Testing
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J. INGIMARSSON, A. THORSTEINSSON, A. LARSSON, and O. WERNER
Lung and Chest Wall Mechanics in Anesthetized Children . Influence of Body Position
Am. J. Respir. Crit. Care Med., August 1, 2000; 162(2): 412 - 417.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
J. Stocks
Assessment of lung function in infants
Perfusion, January 1, 1993; 8(1): 71 - 80.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online