Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 48: 982-990, 1980;
8750-7587/80 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sasaki, H.
Right arrow Articles by Nakamura, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sasaki, H.
Right arrow Articles by Nakamura, M.

Journal of Applied Physiology, Vol 48, Issue 6 982-990, Copyright © 1980 by American Physiological Society


ARTICLES

Collateral resistance at alveolar level in excised dog lungs

H. Sasaki, T. Takishima and M. Nakamura

In excised dog lungs, collateral resistance was measured among separate groups of alveoli. Alveoli beneath the pleural surface were multipunctured by a small needle, and alveolar pressure and flow were measured in capsules glued onto the punctured pleural surface. When the airway opening was closed, collateral ventilation appeared to occur mainly through the regular airway system, but not through the collateral channels. When the airway opening and the segmental bronchus were occluded, collateral airflow appeared to occur first, within the segment through its airway system; second, through the intersegmental collateral channels to other segments; and third, to output alveoli through the airway system. When the airway was obstructed down to the bronchilar level with silicone rubber, collateral resistance became extremely high. It was concluded that collateral resistantce at the alveolar level was considerably higher than the resistance in the regular airway system.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
Z. Hantos, F. Petak, A. Adamicza, T. Asztalos, J. Tolnai, and J. J. Fredberg
Mechanical impedance of the lung periphery
J Appl Physiol, November 1, 1997; 83(5): 1595 - 1601.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online