Journal of Applied Physiology http://www.adinstruments.com/labchart/faseb
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 48: 933-938, 1980;
8750-7587/80 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Auchincloss, J. H.
Right arrow Articles by Peppi, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Auchincloss, J. H.
Right arrow Articles by Peppi, D.

Journal of Applied Physiology, Vol 48, Issue 6 933-938, Copyright © 1980 by American Physiological Society


ARTICLES

Mixed venous CO2 tension during exercise

J. H. Auchincloss, R. Gilbert, M. Kuppinger and D. Peppi

A series of experiments was undertaken in a total of 95 adult subjects, of whom 25 had coronary artery disease, to evaluate the extrapolation (Defares) CO2 rebreathing method vs. the equilibrium (Collier) method for estimating mixed venous CO2 tension. Collier values were corrected for the downstream effect, whereas Defares values were uncorrected. Although the methods gave similar mean values in separate series with normal subjects walking on a treadmill set at 123 W for 3 min, Collier values had a coefficient of variation (CV) of 2.5% in duplicate determinations and Defares values had a CV of 4.5%. In paired comparisons Defares values averaged either higher or lower than Collier values depending on variations in technique and the analysis of Defares tracings. Collier values were essentially unaffected by the duration of the rebreathing period (10 vs. 15 s). The Collier technique appears to be superior for the exercise evaluation of cardiac output in healthy and diseased subjects when the goal is obtain values at 82 or 123 W in single test sessions.


This article has been cited by other articles:


Home page
Eur Heart JHome page
A. Alonso-Fernandez, F. Garcia-Rio, M. A. Arias, O. Mediano, J. M. Pino, I. Martinez, and J. Villamor
Obstructive sleep apnoea-hypoapnoea syndrome reversibly depresses cardiac response to exercise